Comparative Evaluation of Two Types of Immediately Loaded Implants Using Biomechanical and Histomorphometric Tests: An Animal Case Study

Author:

Rismanchian Mansour1,Movahedian Bijan2,Khalighinejad Navid3,Badrian Hamid3ORCID,Mohammad Razavi Sayed4,Nekouie Afsaneh5

Affiliation:

1. Dental Implant Research Center and Prosthodontics Department, Dental School, Isfahan University of Medical Sciences, Hezarjerib Street, Isfahan 8174673461, Iran

2. Torabinejad Dental Research Center and Oral and Maxillofacial Surgery Department, Dental School, Isfahan University of Medical Sciences, Hezarjerib Street, Isfahan 8174673461, Iran

3. Dental Implant Research Center, Dental School, Isfahan University of Medical Sciences, Hezarjerib Street, Isfahan 8174673461, Iran

4. Torabinejad Dental Research Center and Oral Pathology, Dental School, Isfahan University of Medical Sciences, Hezarjerib Street, Isfahan 8174673461, Iran

5. Dentistry Department, Dental School, Isfahan University of Medical Sciences, Hezarjerib Street, Isfahan 8174673461, Iran

Abstract

Introduction. In order to minimize the required time to regain esthetic and function, immediately loaded implants were suggested. The aim of this study was to comparatively evaluate the Nisastan and XIve implants using biomechanical and histomorphometric tests. Materials and Methods. In this experimental study, 6 Nisastan one-piece immediately loaded screw type implant (OPILS) and 6 Xive implants with 3.4 mm diameter and 11 mm long were used. The implants were immediately loaded with temporary coating. After three months, the torque required to break bone-implant contact was measured and was recorded. All implants were extracted with surrounding bone and histologically were evaluated. The data were inputted into the SPSS 11.5 to run student T-test statistical analyses (). Results. The success rates of both types of implants was 100%, and none of them failed due to mobility or bone loss. The mean removal torque value (RTV) was 142.08 and 40 N/Cm for Xive and Nisastan implants, respectively, and their RTVs showed a significant difference between two mentioned implants (). None of the histomorphometric values showed significant differences between the two implants (). Discussion. both systems have the capability to induce osseointegration under immediate loads but that Xive implants showed higher capability for bone contact.

Publisher

Hindawi Limited

Subject

Management of Technology and Innovation

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3