Assessing the Accuracy of Bone Resection by Cutting Blocks in Patient-Specific Total Knee Replacements

Author:

Yeo Cheng Hong12,Jariwala A.3,Pourgiezis N.4,Pillai A.56

Affiliation:

1. Division of Orthopaedics and Trauma, The Queen Elizabeth Hospital, Adelaide, SA 5011, Australia

2. Department of Orthopaedic and Trauma Surgery, Toowoomba Hospital, Toowoomba, QlD, Australia

3. Department of Orthopaedic and Trauma Surgery, TORT Centre, Ninewells Hospital and Medical School, University of Dundee, Dundee DD19SY, UK

4. The Queen Elizabeth Hospital, Adelaide, SA 5011, Australia

5. Department of Orthopaedic and Trauma Surgery, Ninewells Hospital, Ward 18-19, Level 5, Dundee, UK

6. The University of Adelaide, Adelaide, SA 5005, Australia

Abstract

Introduction. The key to a successful total knee arthroplasty (TKA) is the restoration of the mechanical axis with balanced flexion and extension gaps. Patient-specific cutting block technique has been the latest development in total knee arthroplasty. This technique uses a magnetic resonance image (MRI) of the patient's symptomatic knee to create bone models and cutting jigs. This study was designed to evaluate the intraoperative accuracy of the patient-specific cutting block as compared to the preoperative template. Methods. Visionaire (Smith and Nephew, Genesis 2 Knee Arthroplasty) patient-specific TKA was used in all patients. An independent research officer was responsible for measuring all the resected articular surfaces of femur and tibia during surgery and compared it to the cutting block manufactured according to the preoperative template. Seven different measurements from each patient were obtained; four different measurements from the femur and three from the tibia were recorded. The differences between the actual resections made intraoperatively, as compared to the original pre-operative templates, were noted as the error. The surgical team was blinded to the measurements of the resections and the calculations of the errors. Results. Twenty-six Visionaire patient-specific TKA were included in the study. A total of 182 readings of bone resections made intraoperatively (seven for each patient). Eighty five percent of all collected readings were below the error margin of ≤1.5 mm. Size of resection had no effect on the error margin. All patients had satisfactory post-operative alignment, and at discharge all 26 patients achieved more than 90° of knee flexion. Conclusion. This observational study provides evidence that patient-specific TKA is comparable to other forms of TKA and may have some distinct advantages. In addition, we have shown that the cutting blocks are able to consistently deliver accurate cuts that are reproducible. We recommend intra-operative measurement of the bone resection and its comparison with the cutting block as a routine surgical step to confirm the MRI scan data, block placement, and instant validation of the bony resection before implant placement.

Publisher

Hindawi Limited

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3