Low dose protocol for high resolution CT thorax: influence of matrix size and tube voltage on image quality and radiation dose

Author:

Kumar Navish,Pradhan Abhimanyu,Kadavigere RajagopalORCID,Sukumar SureshORCID

Abstract

Background: High-resolution CT (HRCT) thorax has increase demand due to its advantage in diagnosing chronic respiratory diseases. The feasibility of matrix size with different tube voltage in the HRCT protocol of thorax is unknown. Therefore, this study aimed to compare the effect of matrix sizes and tube voltage on image quality and radiation dose on adult HRCT thorax.   Methods: A Phantom experiment was performed, followed by a patient scan. For phantom and patient scan, a total of six protocols with two tube voltage settings, 120 kVp and 100 kVp, with a combination of three matrix sizes, 512, 768, and 1024 were used. In this study, 180 adult patients who had HRCT thorax scan were considered. Dose data was collected, and quantitative image analysis was performed by drawing region of interests on the acquired phantom and patient images. Qualitative image analysis was performed independently by two blinded radiologists.   Results: The dose report of the phantom experiment revealed that the 100kVp with selected matrix size delivered 15.64% and 15.62% less radiation dose in terms of volumetric computed tomography dose index (CTDIvol) and dose length product (DLP), respectively, compared to 120kVp settings with selected matrix sizes. Similarly, for the patient population, the CTDIvol and DLP difference noted for 120kVp and 100kVp with different matrix sizes was statistically significant (p<0.001). For quantitative image quality, the difference noted was also statistically significant among two kVp settings. The mean score for subjective image assessment was greater than 4.5 for diagnostic acceptability and streak artefacts.   Conclusion: The result suggests that the 100 kVp with 512 X 512 matrix size is preferable in the HRCT Lung to achieve the optimal diagnostic image quality with a reduction of almost 40% of the dose to the patients compared to 120 kVp techniques.

Funder

Manipal Academy of Higher Education

Publisher

F1000 Research Ltd

Subject

General Pharmacology, Toxicology and Pharmaceutics,General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3