The STArgardt Remofuscin Treatment Trial (STARTT): design and baseline characteristics of enrolled Stargardt patients

Author:

Dhooge Patty P.A.ORCID,Möller Philipp T.,Boon Camiel J.F.,Lotery Andrew J.,Herrmann Philipp,Battaglia Parodi Maurizio,Klein Wolfgang,Fsadni Mario G.,Wheeler-Schilling Thomas H.,Jungmann Oliver,Müller Hans,Holz Frank G.,Schmitz-Valckenberg SteffenORCID,Peters Tobias M.,Stingl Katarina,Hoyng Carel B.,

Abstract

Background: This report describes the study design and baseline characteristics of patients with Stargardt disease (STGD1) enrolled in the STArgardt Remofuscin Treatment Trial (STARTT). Methods: In total, 87 patients with genetically confirmed STGD1 were randomized in a double-masked, placebo-controlled proof of concept trial to evaluate the safety and efficacy of 20 milligram oral remofuscin for 24 months. The primary outcome measure is change in mean quantitative autofluorescence value of an 8-segment ring centred on the fovea (qAF8). Secondary efficacy variables are best corrected visual acuity (BCVA), low-luminance visual acuity (LLVA), mesopic microperimetry (mMP),  spectral domain optical coherence tomography (SD-OCT), reading speed on Radner reading charts, and patient-reported visual function as assessed by the National Eye Institute Visual Functioning Questionnaire 25 (NEI VFQ-25) and Functional Reading Independence (FRI) Index. Results: Mean age of participants was 35±11 years with 49 (56%) female. Median qAF8 value was 438 Units (range 210-729). Median BCVA and LLVA in decimal units were 0.50 (range 0.13-0.80) and 0.20 (range 0.06-0.63), respectively. The median of the mean retinal sensitivity with mMP was 20.4 dB (range 0.0-28.8). SD-OCT showed median central subfield retinal thickness of 142 µm (range 72-265) and median macular volume of 1.65 mm3 (range 1.13-2.19). Compared to persons without vision impairment, both reading performance and patient-reported visual function were significantly lower (p<0.001, one sample t-test). Mean reading speed was 108±39 words/minute with logRAD-score of 0.45±0.28. Mean VFQ-25 composite score was 72±13. Mean FRI Index score 2.8±0.6. Conclusions: This trial design may serve as reference for future clinical trials as it explores the utility of qAF8 as primary outcome measure. The baseline data represent the largest, multi-national, STGD1 cohort to date that underwent standardized qAF imaging, reading speed assessment and vision-related quality of life measures which all contribute to the characterization of STGD1. EudraCT registration: 2018-001496-20 (09/05/2019)

Funder

Horizon 2020 Framework Programme

Publisher

F1000 Research Ltd

Subject

Ocean Engineering,Safety, Risk, Reliability and Quality

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3