Dosimetric Evaluation and Comparison of Collapsed Cone Algorithm with AAA and AcurosXB Algorithms for Lung Cancer Treatment Planning on the Varian Halcyon Accelerator

Author:

Shao Kainan1,Du Fenglei2,Qiu Lingyun1,Zhang Yinghao1,Li Yucheng1,Ding Jieni1,Zhan Wenming1,Chen Weijun1

Affiliation:

1. Zhejiang Provincial People's Hospital

2. Zhejiang Cancer Hospital

Abstract

Abstract Objective: This study aims to compare the dosimetric calculationsin standard non-small cell lung cancer (NSCLC) radiotherapy planningusing the Collapsed Cone (CC) algorithm of the RayStation planningsystem on the Varian Halcyon accelerator, with the Analytical AnisotropicAlgorithm (AAA) and Acuros XB algorithms on the Eclipse accelerator. Methods: The RayStation planning system was employed to designthe RapidArc radiotherapy plans for 15 lung cancer patients on theHalcyon accelerator, using the CC algorithm for dose calculation.The plans were then transferred to the Eclipse planning system. Withoutmaking any changes to these plans, doses were computed using bothAAA and Acuros XB algorithms. The differences in dose-volume indicesfor the clinical target volume (CTV), planned target volume (PTV),and other organs at risk were evaluated. Results:Compared with the CC algorithm, the AAA algorithmshowed slightly lower dose-volume indices for both the CTV (D2%,D50%, D95%, D98%, and mean dose) and the PTV (D2%, D50%, andmean dose), with differences within 1%. Specifically, the PTV's D95%and D98% were respectively 1.7% and 2.4% lower, the heart's meandose was 3.2% lower, the lung's V20Gy was 0.2% lower, the averagedose was 0.2% higher, and the spinal cord's maximum dose (representedby D0.1cc) was 0.9% lower. In contrast to the CC algorithm, the AcurosXB algorithm also showed slightly lower dose-volume indices for theCTV and the PTV, with differences within 1.5%. Specifically, thePTV's D95% and D98% were respectively 1.6% and 2.3% lower, theheart's mean dose was 4.4% lower, the lung's V20Gy was 0.3% lower,the average dose was 1.4% lower, and the spinal cord's maximum dosewas 2.3% lower. Paired t-tests indicated that all these results hadsignificant differences (p<0.05). Conclusion: This study aimed to quantify the impact of usingRayStation system and CC algorithm on Halcyon accelerator for clinicaldose evaluations, by comparing it with the AAA and Acuros XB algorithmsof the Varian Eclipse planning system. For lung cancer radiotherapyplanning, dose calculations obtained from the AAA and Acuros XB algorithmsunder the Eclipse system were slightly lower compared to the RayStationCC algorithm across various clinical indices. Notably, the differencesin the PTV's D95% and D98% indices were over 1.5%, while dose indicesfor various organs at risk were approximately 23% lower. The results of this study can serve as a reference for institutionsthat are preparing to use the RayStation planning system for the designand clinical application of plans on the Varian Halcyon accelerator.

Publisher

Research Square Platform LLC

Reference51 articles.

1. Nguyen, Daniel and Pietri, Florentin Josserand and Sporea, Cristina and Khodri, Mustapha (2018) 17 Patient Quality assurance of the new halcyon linear accelerator (Varian). Physica Medica 56: 10-11 https://doi.org/10.1016/j.ejmp.2018.09.030, 2022-11-12, :nguyen2018.pdf:PDF, 12

2. Mbewe, Jonathan and Shiba, Sakhele (2021) Dosimetric Comparison between Varian Halcyon Analytical Anisotropic Algorithm and Acuros XB Algorithm for Planning of RapidArc Radiotherapy of Cervical Carcinoma. Progress in Medical Physics 32: 130-136 https://doi.org/10.14316/pmp.2021.32.4.130, 2022-01-23, :Dosimetric Comparison between Varian Halcyon Analytical Anisotropic Algorithm and Acuros XB Algorithm for Planning of RapidArc Radiotherapy of Cervical Carcinoma.pdf:PDF, 12

3. Smilowitz, Jennifer and Das, Indra and Feygelman, Vladimir and Fraass, Benedick and Kry, Stephen and Marshall, Ingrid and Mihailidis, Dimitris and Ouhib, Zoubir and Ritter, Timothy and Snyder, Michael and Fairobent, Lynne and Staff, Aapm. AAPM Medical Physics Practice Guideline 5.a.: Commissioning and QA of Treatment Planning Dose Calculations -Megavoltage Photon and Electron Beams. :C\:/Users/shaok/OneDrive/ 文 档/Halcyon_Rays/refs/smilowitz2015.pdf:PDF;:smilowitz2015_AAPM Medical Physics Practice Guideline 5.a. Commissioning and QA of Treatment Planning Dose Calculations -Megavoltage Photon and Electron Beams.pdf:PDF, not, 2015

4. Sievinen, Janne and Ulmer, Waldemar and Kaissl, Wolfgang and others (2005) AAA photon dose calculation model in Eclipse. Palo Alto (CA): Varian Medical Systems 118: 2894 Citeseer, :AAA photon dose calculation model in EclipseTM.pdf:PDF

5. Akpochafor, MO and Aweda, MA and Durosinmi-Etti, FA and Adeneye, SO and Omojola, AD (2014) Simulation of the linear Boltzmann transport equation in modelling of photon beam data. IOSR J Appl Phys 5(6): 72--86 :H0567286.pdf:PDF;:Simulation of the linear Boltzmann transport equation in modelling of photon beam data.pdf:PDF

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3