Affiliation:
1. Shanghai East Hospital
Abstract
Abstract
Background
Internal fixation of the femoral neck carries a risk of perforation due to the presence of the isthmus of the femoral neck. At present, there are few studies on the safe and risk zones of the femoral neck system (FNS) implantation. This study aimed to recommend the safe range of injection of FNS in the lateral wall of the proximal femur, parallel to the axis of the femoral neck, during FNS treatment of femoral neck fracture (FNF).
Methods
Femoral computed tomography (CT) data of 80 patients (male: 40; female: 40) who met the inclusion criteria were collected. Mimics 21.0 software was used to complete the modeling. 3-Matic 13.0 software was used to establish the axis of the femoral neck and its vertical plane, perform the cutting of the femoral neck, and project it on the vertical plane of the femoral neck axis. After matching a rectangle for each projection map, all sample sizes (80 cases) were standardized and superimposed to obtain gradient maps of the safe zone (SZ) and dangerous zone (RZ), thereby securing edge key points and safe FNS insertion range.
Results
In the 80 samples, the mean diameter of the smallest femoral neck section was 33.87 ± 2.32 mm for men and 29.36 ± 1.92 mm for women. All 80 femoral necks had safe and risky areas. The SZ/S × 100% was 77.59 (± 2.22%), and the RS/S ×100% was 22.39% (± 2.22%). The risk area was composed of four parts: (1), (2), (3), and (4), respectively, corresponding to 3.45 ± 1.74%, 5.51 ± 2.63%, 6.22 ± 1.41%, and 7.22 ± 1.39%. Four marginal key points, perforation risk, and safe ranges (SR) of FNS were analyzed on the lateral wall of the femoral neck.
Conclusions
The SR of FNS placement was recommended by digital simulation. In addition, Regions (3) and (4) posed a higher risk of penetrating the cortex. Using the gradient map of RZ for preoperative evaluation is recommended to avoid iatrogenic perforation.
Publisher
Research Square Platform LLC