Evaluation of quality control and initial imaging properties of labeled [68Ga]GaPSMA-11 by elution of Monrol [68Ge]/[68Ga] generator

Author:

Yüksel Doğangün1,Uğur Ayşe1ORCID,Yaylalı Olga1,Şengöz Tarık1,Gültekin Aziz1,Arslan Duygu2

Affiliation:

1. Pamukkale University: Pamukkale Universitesi

2. TUBITAK Butal: Tubitak Bursa Test ve Analiz Laboratuvari

Abstract

Abstract Background: The [68Ga]Cl3 precursor is not commercially available as a raw material or as a [68Ga]-labeled radiopharmaceutical. [68Ge]/[68Ga] generators are household type generators used to obtain [68Ga] radionuclide. In this study, the product quality control parameters of [68Ga]GaPSMA-11 radiotracer labeled with [68Ga]Cl3 obtained from a GMP certified [68Ge]/[68Ga] generator manufactured by “Eczacıbaşı Monrol Nuclear Products Co.” (Turkey) were investigated. We evaluated and reported the quality control data and the first clinical patient studies with this radiotracer. Biodistribution of [68Ga]-radiotracer by PET-CT was evaluated retrospectively. Twenty one patients with prostate cancer who agreed to participate in the study were included and underwent [68Ga]GaPSMA-11 injection and PET-CT imaging. Results: The initial elution yield of the generator was determinde as 75% with reproducible stability. The amount of [68Ga] in the eluate by the HCl elution fraction was found to be appropriate. Of the 21 patients referred to our department, 10 patients were included in the study for staging and 11 patients for evaluation of response to treatment. The [68Ga]GaPSMA-11 uptake was observed in primary tumor and metastasis foci in 11 patients with metastatic prostate cancer. Heterogeneous [68Ga]GaPSMA-11 uptake was observed in prostate cancer and metastasis areas. Conclusion: [68Ga]GaPSMA-11 radiopharmaceutical was synthesized from a new generator with good quality and satisfying PET-CT images were obtained.

Publisher

Research Square Platform LLC

Reference18 articles.

1. Gallium–68 ethylenediamine tetraacetic acid (EDTA) imaging of brain tumors by positron tomography;Wong DF;J Nucl Med,1984

2. An improved gallium–68 cow;Greene MW;Int J Appl Radiat Isot,1961

3. A gallium–68 positron cow for medical use;Yano Y;J Nucl Med,1964

4. Past, present and future of 68Ge/68Ga generators;Rösch F;Appl Radiat Isot,2013

5. Razbash AA, Sevastianov YuG, Krasnov NN, Leonov AI, Pavlekin VE. Germanium–68 row of products. In: Proceedings of the 5th International Conference on Isotopes, 5ICI, Brussels, Belgium, Medimond, Bologna, 2005; 25–29, 147.