Development of A Simplified New Method of Bone Age Estimation Using Three Bones of the Hand and Wrist

Author:

Khadilkar Vaman1,Mondkar Shruti Arvind1,Desai Keyur Bhavesh2,Oza Chirantap1,Yewale Sushil1,Dange Nimisha1,Lohiya Nikhil3,Patil Prashant4,Prasad Hemchand Krishna5,Shah Nikhil6,Karguppikar Madhura7,Maheshwari Ankita8,Khadilkar Anuradha V1ORCID

Affiliation:

1. Department of Growth and Pediatric Endocrinology, Hirabai Cowasji Jehangir Medical Research Institute, Pune

2. Department of Orthopedics, Adhikari Lifeline Multispeciality Hospital, Boisar

3. Division of Growth and Endocrinology, Silver Lining Pediatric Super Speciality Centre for Growth, Development and Endocrine Care, Nagpur

4. SRCC NH Children's Hospital, Mumbai

5. Department of Pediatric Endocrinology, Mehta Hospital, Chennai

6. Division of Pediatric Endocrinology, Department of Pediatrics, Surya Children's Hospital, Mumbai

7. Smt Kashibai Navale Medical College and General Hospital

8. Sri Aurobindo Institute of Medical Sciences

Abstract

Abstract Though the Greulich and Pyle(GP) method is easy, inter-observer variability, differential maturation of hand bones influences ratings. The Tanner-Whitehouse(TW) method is more accurate, but cumbersome. A simpler method combining the above, such that it utilizes fewer bones without affecting accuracy, would be widely used and more applicable in clinical practice. Objectives:1.Devising a simplified method utilizing three bones of the hand and wrist for bone age(BA) assessment. 2.Testing whether the 3 bone method gives comparable results to standard methods (GP,TW2,TW3) in Indian children. Methods:Developmental stages and corresponding BA for radius, hamate, terminal phalanx (left middle finger) epiphyses combining stages from GP,TW3 atlases were described; BA were rated by two blinded observers. 3 bone method ratings were compared with the same dataset analyzed earlier using GP,TW2,TW3(4 raters). Results:Radiographs analysed:493 (Girls = 226). Mean chronological age:9.4 ± 4.6yrs, mean BA 3 bone:9.8 ± 4.8yrs, GP:9.6 ± 4.8yrs, TW3:9.3 ± 4.5yrs, TW2:9.9 ± 5.0yrs. The 3 bone method demonstrated no significant inter-observer variability(p = 0.3, mean difference = 0.02 ± 0.6yrs); a strong positive correlation (p < 0.0001) with GP(r = 0.985), TW3(r = 0.983) and TW2(r = 0.982) was noted. Bland-Altman plots demonstrated good agreement; the root mean square errors between 3 bone and GP,TW3,TW2 ratings were 0.6,0.7,0.6 years; mean differences were 0.19,0.49,-0.14 years respectively. Greatest proportion of outliers (beyond ± 1.96SD of mean difference) was between 6–8 years age for difference in 3 bone and GP, and between 4–6 years for difference in 3 bone and TW3,TW2. Conclusion:The 3 bone method has multiple advantages;it is easier, tackles differential maturation of wrist and hand bones, has good reproducibility, without compromising on accuracy rendering it suitable for office practice.

Publisher

Research Square Platform LLC

Reference22 articles.

1. Traditional and new methods of bone age assessment-an overview;Prokop-Piotrkowska M;J. Clin. Res. Pediatr. Endocrinol.,2021

2. W.W. Greulich, S. Pyle, Radiographic atlas of skeletal development of the hand and wrist (Stanford University Press, Stanford, 1959)

3. Effect of training on replicability of assessments of skeletal maturity (Greulich-Pyle);Roche AF;Am. J. Roentgenol. Radium Ther. Nucl. Med.,1970

4. A comparison of bone age assessments using automated and manual methods in children of Indian ethnicity;Oza C;Pediatr. Radiol.,2022

5. Analysis of interrater reliability in age assessment of minors: how does expertise influence the evaluation?;Franceschetti L;Int. J. Legal Med.,2022

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3