Optimizing IOL calculation in triple-DMEK: data from a real-life cohort

Author:

Velarde-Rodríguez Gonzalo1,Lorenzana-Blanco Natalia1,Corte-Alonso Sofía1,Garcia-Sandoval Blanca1,Morote Ignacio Jiménez-Alfaro2,Alejandre-Alba Nicolás1

Affiliation:

1. Fundación Jiménez Díaz University Hospital

2. Fundacion Jimenez Diaz

Abstract

Abstract

Aim To enhance the accuracy of intraocular lens (IOL) power calculation in patients undergoing simultaneous cataract surgery and Descemet membrane endothelial keratoplasty (triple-DMEK) by predicting corneal power changes.Methods Observational ambispective monocentric cohort study. Real life refractive outcomes and pre/post-operative corneal data from the IOL Master 700 (Zeiss) were merged in a linear corneal change model (LCCM), including traditional and new-generation formulae. The model was compared with the outcomes of optimizing IOL constants specifically for Triple-DMEK.Results 97 eyes of 69 patients with a follow-up of more than 3 months were analysed. Preoperative keratometry was unavailable in 9 eyes, in which IOL calculation was performed by manually with autorefractometer data and were analysed separately. Mean absolute error (MAE) for the former group was higher than for the measured one, 1.35 ± 1.16 D and 0.75 ± 0.70 D respectively. The median change in simulated keratometry (SimK) was − 0.21 ± 0.68 D and in total keratometry (TK) was − 0.62 ± 1.09 D, both statistically significant (p < 0.001). The lowest MAE was achieved by SRK/T with constant optimization (0.60 ± 0.58 D). The LCCM applied to any formula, showed similar MAE results to the constant optimization method (p > 0.05). However, the maximum absolute error for the optimization method was 2.08 ± 0.16 D, while for the LCCM method was 1.87 ± 0.13 D.Conclusions Keratometric readings in corneas with Fuchs´ dystrophy should be carefully measured. SimK and TK show a significant change during Triple-DMEK surgery. Optimizing IOL constants for this surgery improves the MAE, while using the LCCM could lead to a reduction of refractive surprises.

Publisher

Springer Science and Business Media LLC

Reference28 articles.

1. Intra-ocular acrylic lenses; a recent development in the surgery of cataract;Ridley H;Br J Ophthalmol,1952

2. Pursuing perfection in intraocular lens calculations: I. Logical approach for classifying IOL calculation formulae;Koch DD;J Cataract Refract Surg,2017

3. [A method of calculating the optical power of the intraocular lens];Fedorov SN;Vestn Oftalmol,1967

4. Update on Intraocular Lens Formulae and Calculations;Xia T;Asia-Pac J Ophthalmol Phila Pa,2020

5. Pre-clinical estimation of the intraocular lens A-constant, and its relationship to power, shape factor, and asphericity;Simpson MJ;Appl Opt,2021

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3