Correlation study of changes in visual acuity, pupil diameter, Kappa angle, and Alpha angle after phacoemulsification surgery combined with multifocal IOL implantation

Author:

Zhenlin Lin1,Pengfen Gao2,Honghua Zheng3

Affiliation:

1. Master of Fujian University of Traditional Chinese Medicine, Fuzhou Aier Eye Hospital Group Company Limited

2. Doctor of WEIFANG Medical University, Fuzhou Aier Eye Hospital Group Company Limited

3. Doctor of Fujian Medical University, Fuzhou Aier Eye Hospital Group Company Limited

Abstract

Abstract Purpose To study the changes and correlation of visual acuity, pupil size, kappa angle and Alpha angle after phacoemulsification combined with multifocal intraocular lens implantation by analyzing the data provided by OPD-ScanIII Optical Path Difference optical path difference analyzer. Methods From March 2020 to October 2021, 35 patients (60 eyes) with cataract who underwent phacoemulsification combined with multifocal intraocular lens implantation were analyzed retrospectively. The changes of pupil size, Alpha angle, Kappa angle and postoperative visual acuity were measured by OPD-ScanIII optical path difference analyzer before and 1 week after operation. The correlation between pupil size, Kappa angle, Alpha angle and distal and near visual acuity was analyzed 1 week and 1 month after operation. Sixteen eyes of cataract patients were followed up for more than one month to study the changes of pupil size, Alpha angle and Kappa angle one week and one month after operation. Results phacoemulsification combined with multifocal intraocular lens implantation significantly improved the visual acuity of the patients, and the pupil size and Kappa angle decreased 1 week after operation, but there was no significant difference between the indexes more than one month after operation and those before operation. There was no significant difference in Kappa angle and Alpha angle before and 1 week after operation, but there was significant correlation between distant visual acuity and Kappa angle in light and dark vision 1 week after operation. There was no correlation between distant visual acuity and Alpha angle and pupil size 1 week after operation. One week after operation, there was no correlation between near and middle visual acuity and Alpha angle, Kappa angle and pupil size 1 week after operation, and there was no significant difference between Alpha angle and Kappa angle and pupil size 1 week after operation. There was no significant difference between Alpha angle and Kappa angle 1 month after operation. Conclusion phacoemulsification combined with bifocal intraocular lens implantation can significantly improve the visual acuity of patients, reduce the size of light and dark pupil and Kappa angle under dark vision in a short time, and recover after long-term surgery. Therefore, phacoemulsification combined with bifocal intraocular lens surgery should not expand the optical related indexes of patients before operation, which may lead to postoperative adverse reactions and decrease satisfaction.

Publisher

Research Square Platform LLC

Reference31 articles.

1. Alio Jorge L,Plaza-Puche Ana B,Férnandez-Buenaga Roberto et al. Multifocal intraocular lenses:An overview.[J].Surv Ophthalmol,2017,62:611–634.

2. Annette Harrer,Nino Hirnschall,Juan Tabernero,Pablo Artal,Petra Draschl,Sophie Maedel,Oliver Findl,Variability in angle k and its influence on higher-order aberrations in pseudophakic eyes,Journal of Cataract & Refractive Surgery,Volume 43,Issue8,2017,Pages1015-1019,ISSN0886-3350,https://doi.org/10.1016/j.jcrs.2017.05.028.

3. Naroo Shehzad A,Eperjesi Frank,Evaluation of the auto-refraction function of the Nidek OPD-Scan III.[J];McGinnigle Samantha;Clin Exp Optom,2014

4. [Presbyopia Correction with Intraocular Lenses].[J];Knorz Michael C;Klin Monbl Augenheilkd,2020

5. Karhanová Marta,Pluháček František,Mlčák Petr et al.The importance of angle kappa evaluation for implantation of diffractive multifocal intra-ocular lenses using pseudophakic eye model.[J].Acta Ophthalmol,2015,93:e123-8.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3