Calcium Scoring with Prospective ECG-Triggered coronary CT Angiography: A Path to Reduce Radiation Dose

Author:

Hagar Muhammad Taha1,Soschynski Martin1,Benndorf Matthias2,Stein Thomas1,Taron Jana1,Schlett Christopher L.1,Bamberg Fabian1,Krauß Tobias1

Affiliation:

1. Department for Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, Albert-Ludwigs-University of Freiburg

2. Institute for Diagnostic and Interventional Radiology, Campus Lippe Hospital, University Hospital OWL

Abstract

Abstract Objectives: To examine if calcium scoring CT (CAS-CT) reduces the whole-examination radiation dose of prospectively ECG-triggered coronary CT-angiography (CCTA). Methods In this retrospective study, patients underwent CAS-CT and prospectively ECG-triggered CCTA on a 2nd generation Dual-Source CT scanner. CCTA was planned on CAS-CT images. We further simulated CCTA-planning on scout-view. Therefore, the scan length of the scout-view-derived CCTA was set equal to the CAS-CT scan length. Effective doses were compared for the following scenarios: (1) CAS-CT-derived CCTA + CAS-CT and (2) scout-view-derived CCTA without CAS-CT. Dose differences between the scenarios were additionally examined with respect to scan mode and body-mass-index. Results Among 182 patients (58±12 years, 47% females), planning cCTA on CAS-CT resulted in a shorter scan length than planning on scout-view (114.3 ± 9.7 mm vs 133.7 ± 13.2 mm, p<0.001). The whole-examination effective dose was slightly lower for scenario (1) (3.2 [1.8 – 5.3] mSv vs 3.4 [1.5 – 5.9] mSv; p<0.001, n=182). Scenario (1) resulted in a substantially lower radiation dose in sequential scans (3.6 [2.3 – 6.1] mSv vs 3.9 [2.4 – 6.50] mSv, n=150), or in obese patients (6.8 mSv [4.5 – 9.1]) vs 7.3 mSv [4.7 – 9.9], n=45), p<0.001 respectively. Only in high-pitch spiral CCTA, scenario (2) resulted in a dose salvage (0.8 mSv [0.6 – 1.4] vs 1.0 mSv [0.8 – 1.5], n=32; p<0.001). Conclusions Planning prospectively ECG-triggered CCTA on CAS-CT reduces the overall radiation dose of the examination compared to a scout-view planning approach where no CAS-CT is acquired. Only for high-pitch spiral CCTA a slightly opposite effect was observed.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3