Usefulness of impulse oscillometry in predicting the severity of bronchiectasis

Author:

Choi Ji Soo1,Kwak Se Hyun1,Kim Min Chul1,Seol Chang Hwan1,Heo Seok-Jae1,Kim Sung Ryeol1,Lee Eun Hye1

Affiliation:

1. Yonsei University College of Medicine

Abstract

Abstract Background: Bronchiectasis is a chronic respiratory disease that leads to airway inflammation, destruction, and airflow limitation, which reflects its severity. Impulse oscillometry (IOS) is a non-invasive method that uses sound waves to estimate lung function and airway resistance. The aim of this study was to assess the usefulness of IOS in predicting the severity of bronchiectasis. Methods: We retrospectively reviewed the IOS parameters, clinical characteristics, and results of other examinations in 145 patients diagnosed with bronchiectasis between March 2020 and May 2021. Disease severity was evaluated using the FACED score, and patients were divided into mild and moderate/severe groups. Results: Forty-four patients (30.3%) were in the moderate/severe group, and 101 (69.7%) were in the mild group. The mean predicted forced expiratory volume in one second was 78.0% in the mild group and 54.5% in the moderate/severe group. Patients with moderate/severe bronchiectasis had a higher airway resistance at 5 Hz (R5) (0.53 vs. 0.41, p <0.001), a higher difference between the resistance at 5 and 20 Hz (R5 − R20; 39.85 vs. 26.81, p <0.001), a higher resonant frequency (Fres) (22.52 vs. 17.54, p <0.001), and a higher reactance area (AX) (2.44 vs. 1.06, p <0.001) than patients with mild bronchiectasis. R5 ≥0.43, R20 ≥0.234, R5 − R20 ≥28.3, AX ≥1.02, reactance at 5 Hz (X5) ≤−0.238, and Fres ≥20.88 revealed significant univariable relationships with bronchiectasis severity (p-values <0.05). Among these, only X5 ≤−0.238 exhibited a significant multivariable relationship with bronchiectasis severity (p = 0.039). The receiver operating characteristic curve for the severity of bronchiectasis based on IOS parameters exhibited an area under the curve of 0.809. Conclusions: The IOS parameters can effectively reflect airway resistance and elasticity in patients with bronchiectasis and serve as valuable tools for predicting bronchiectasis severity.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3