Regression fitting megavoltage depth dose curves to determine material relative electron density in radiotherapy.

Author:

Karl Anthony Simon1ORCID,Steel Jared G1,Warr George B2

Affiliation:

1. Mid North Coast Cancer Institute

2. Western Cancer Centre Dubbo

Abstract

Abstract The relative electron density (RED) parameter is ubiquitous throughout radiotherapy for clinical dosimetry and treatment planning purposes as it provides a more accurate description of the relevant radiological properties over mass density alone [1]. RED is theoretically derived and in practice determined indirectly from calibrated CT Hounsfield Units (HU) [1]. While CT images provide useful 3D information, the spectral differences between CT and clinical LINAC beams may impact the validity of the CT-ED calibration, especially in the context of novel tissue-mimicking materials where deviations from biologically typical atomic number to atomic weight ratios < Z/A > occur and/or high-Z materials are present [2]. A theoretical basis for determining material properties directly in a clinical beam spectrum via an electron-density equivalent pathlength (eEPL) method has been previously established [2]. An experimental implementation of this approach is introduced whereby material-specific measured percentage depth dose curves (PDDs) are regressed to a PDD measured in a reference material (water), providing an inference of < Z/A>, which when combined with the physical density provides a determination of RED. This method was validated over a range of tissue-mimicking materials and compared against the standard CT output, as well as compositional information obtained from the manufacturer's specifications. The measured PDD regression method showed consistent results against both manufacturer-provided values and CT-derived within 0.9 and 1.15 RED. Outside of this soft-tissue range a trend was observed whereby the < Z/A > determined becomes unrealistic indicating the method is no longer reporting RED alone and the assumptions around the eEPL model are constrained. Within a range of validity, the regression method provides a practical and robust characterisation for unknown materials in the clinical setting and may be used to improve on the CT output where high Z material components are suspected.

Publisher

Research Square Platform LLC

Reference31 articles.

1. The calibration of CT Hounsfield units for radiotherapy treatment planning;Schneider U;Phys Med Biol

2. Seco J, Evans PM (2006) “Assessing the effect of electron density in photon dose calculations: Effect of electron density in photon dose calculations,” Medical Physics, vol. 33, no. 2, pp. 540–552, Jan. doi: 10.1118/1.2161407

3. McGarry CK et al (2020) “Tissue mimicking materials for imaging and therapy phantoms: a review,” Physics in Medicine & Biology, doi: 10.1088/1361-6560/abbd17

4. A. P et al., “Absorbed Dose Determination in External Beam Radiotherapy: an international code of practice for dosimetry based on standards of absorbed dose to water IAEA Technical Report Series No 398 International Atomic Energy Agency,” w, [Online]. Available: https://www.iaea.org/publications/5954/absorbed-dose-determination-in-external-beam-radiotherapy

5. Advanced Radiation DOSimetry phantom (ARDOS): a versatile breathing phantom for 4D radiation therapy and medical imaging;Kostiukhina N;Phys Med Biol

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3