The relative electron density (RED) parameter is ubiquitous throughout radiotherapy for clinical dosimetry and treatment planning purposes as it provides a more accurate description of the relevant radiological properties over mass density alone [1]. RED is theoretically derived and in practice determined indirectly from calibrated CT Hounsfield Units (HU) [1]. While CT images provide useful 3D information, the spectral differences between CT and clinical LINAC beams may impact the validity of the CT-ED calibration, especially in the context of novel tissue-mimicking materials where deviations from biologically typical atomic number to atomic weight ratios < Z/A > occur and/or high-Z materials are present [2]. A theoretical basis for determining material properties directly in a clinical beam spectrum via an electron-density equivalent pathlength (eEPL) method has been previously established [2]. An experimental implementation of this approach is introduced whereby material-specific measured percentage depth dose curves (PDDs) are regressed to a PDD measured in a reference material (water), providing an inference of < Z/A>, which when combined with the physical density provides a determination of RED. This method was validated over a range of tissue-mimicking materials and compared against the standard CT output, as well as compositional information obtained from the manufacturer's specifications. The measured PDD regression method showed consistent results against both manufacturer-provided values and CT-derived within 0.9 and 1.15 RED. Outside of this soft-tissue range a trend was observed whereby the < Z/A > determined becomes unrealistic indicating the method is no longer reporting RED alone and the assumptions around the eEPL model are constrained. Within a range of validity, the regression method provides a practical and robust characterisation for unknown materials in the clinical setting and may be used to improve on the CT output where high Z material components are suspected.
Publisher
Research Square Platform LLC
Reference31 articles.
1. The calibration of CT Hounsfield units for radiotherapy treatment planning;Schneider U;Phys Med Biol
2. Seco J, Evans PM (2006) “Assessing the effect of electron density in photon dose calculations: Effect of electron density in photon dose calculations,” Medical Physics, vol. 33, no. 2, pp. 540–552, Jan. doi: 10.1118/1.2161407
3. McGarry CK et al (2020) “Tissue mimicking materials for imaging and therapy phantoms: a review,” Physics in Medicine & Biology, doi: 10.1088/1361-6560/abbd17
4. A. P et al., “Absorbed Dose Determination in External Beam Radiotherapy: an international code of practice for dosimetry based on standards of absorbed dose to water IAEA Technical Report Series No 398 International Atomic Energy Agency,” w, [Online]. Available: https://www.iaea.org/publications/5954/absorbed-dose-determination-in-external-beam-radiotherapy
5. Advanced Radiation DOSimetry phantom (ARDOS): a versatile breathing phantom for 4D radiation therapy and medical imaging;Kostiukhina N;Phys Med Biol