High-resolution computed tomography with scattered X-ray radiation and a single pixel detector

Author:

Shwartz Sharon1ORCID,Yehuda Adi Ban2ORCID,Sefi Or2,Klein Yishay2,Shukrun Rachel3ORCID,Schwartz Hila3,Cohen Eliahu1ORCID

Affiliation:

1. Bar-Ilan University

2. Bar-Ilan University Physics Department and Institute of Nanotechnology and Advanced Materials

3. Bar-Ilan University Physics Department and Institute of Nanotechnology and Advanced Materials & Radiation Safety Department, Soreq Nuclear Research Center

Abstract

Abstract X-ray imaging is a prevalent technique for non-invasively visualizing the interior of the human body and opaque instruments. In most commercial X-ray modalities, an image is formed by measuring the X-rays that pass through the object of interest. However, despite the potential of scattered radiation to provide additional information about the object, it is often disregarded due to its inherent tendency to cause blurring. Consequently, conventional imaging modalities do not measure or utilize these valuable data. In contrast, we propose and experimentally demonstrate a high-resolution technique for X-ray computed tomography (CT) that measures scattered radiation by exploiting computational ghost imaging (CGI). We show that our method can provide sub-200 µm resolution, exceeding the capabilities of most existing X-ray imaging modalities. Our research reveals a promising technique for incorporating scattered radiation data in CT scans to improve image resolution and minimize radiation exposure for patients. The findings of our study suggest that our technique could represent a significant advancement in the fields of medical and industrial imaging, with the potential to enhance the accuracy and safety of diagnostic imaging procedures.

Publisher

Research Square Platform LLC

Reference42 articles.

1. Über eine neue Art von Strahlen: vorläufige Mitteilung;Röntgen WK;Sitzungsber. Phys. Med. Gesell.,1895

2. Barnes, G. T. Contrast and scatter in x-ray imaging. https://doi.org/10.1148/radiographics.11.2.2028065 11, 307–323 (1991).

3. Scattered X-rays in x-ray photography;Wilsey RB;J Franklin Inst,1922

4. Wilsey, R. B. Scattered Radiation in Roentgenography of the Chest. https://doi.org/10.1148/23.2.198 23, 198–201 (1934).

5. Contrast and Fog in Radiography;Luboshez BE;British Journal of Radiology: BIR Section,1927

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3