Stent strut dilation in branch pulmonary artery stenosis following stenting of arterial duct in duct dependent pulmonary circulation

Author:

KONETI NAGESWARA RAO1,BAKHRU SHWETA1,DHULIPUDI BHARGAVI1,RAJAN SAILEELA2,SREE NARAYANASWAMY3

Affiliation:

1. Rainbow Children's Heart Institute

2. Madras Institute of Orthopaedics and Traumatology

3. HEART CENTRE ,UNIVERSITY HOSPITAL OF COLOGNE

Abstract

Abstract Objective To assess the feasibility and outcome of stent strut dilation after arterial duct stenting with associated branch pulmonary artery (BPA) stenosis.Background Stenting of arterial duct in infants with duct dependent pulmonary circulation is technically challenging. Presence of BPA stenosis is a relative contraindication for stent implantation.Methods Infants with duct dependent pulmonary circulation and associated BPA stenosis were assessed either by transthoracic echocardiogram alone or additional computerized tomography (CT) angiogram when required. Following ductal stenting, the stent struts of the stenosed BPA were crossed with an additional 0.014″ coronary guide wire and dilated using coronary balloons (2.0 or 2.5 mm in diameter).Results Seventeen (12 male) patients were considered for the procedure. The median age and weight were 27 days (range 2 to 94) and 2.6 kilograms (range 2.2 to 5) respectively. Fourteen patients (78%) underwent stent strut dilation after arterial duct stenting. Struts to left pulmonary artery was opened in 9 (64%) and right pulmonary artery in 5 (35%). The baseline saturation improved from 66.23 ± 8.9% to 89.29 ± 4.3% after successful strut dilation. Angiographic pulmonary flow improved in all cases. Stent strut dilation could not be done in 3 patients due to unfavorable anatomy. One patient had acute stent thrombosis and died in the hospital. Two others died during follow-up, during an acute febrile illness and gastroenteritis. All survivors underwent cardiac surgery and were on regular follow-up.Conclusions Strut dilation of BPA stenosis is feasible to augment pulmonary blood flow, following arterial duct stenting.

Publisher

Research Square Platform LLC

Reference11 articles.

1. Arterial duct morphology with reference to angioplasty and stenting;Abrams SE;Int J Cardiol,1993

2. The ductus arteriosus and stenoses of the pulmonary arteries in pulmonary atresia;Elzenga NJ;Int J Cardiol,1986

3. Spontaneous acquisition of discontinuous pulmonary arteries;Waldman JD;Ann Thorac Surg,1996

4. Impact of stent of ductus arteriosus and modified Blalock-Taussig shunt on pulmonary arteries growth and second-stage surgery in infants with ductus-dependent pulmonary circulation;Nasser BA;J Saudi Heart Assoc,2020

5. Duct stenting versus modified Blalock-Taussig shunt in neonates with duct-dependent pulmonary blood flow: Associations with clinical outcomes in a multicenter national study;Bentham JR;Circulation,2018

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3