Influence of Decentration of Plate-Haptic Toric Intraocular Lens on Postoperative Visual Quality

Author:

Diao Chunli1,Lan Qianqian1,Liao Jing1,Lu Peng1,Zhou Zhou1,Li Lanjian1,Zeng Siming1,Yao Gang1,Huang Wei1,Chen Qi1,Lv Jian1,Tang Fen1,Li Min1,Xu Fan1

Affiliation:

1. the People's Hospital of Guangxi Zhuang Autonomous Region & Guangxi, Guangxi Academy of Medical Sciences, Guangxi Zhuang Autonomous Region, China

Abstract

Abstract Background: To evaluate the influence of decentration of plate-haptic toric intraocular lens (IOLs) on visual quality. Methods: This study enrolled 78 eyes of 78 patients. Patients in group A were implanted with toric IOLs, and patients in group B were implanted with monofocal IOLs. All patients were divided into group A1 and B1 (decentration below 0.3mm) and group A2 and B2 (decentration above 0.3mm). The uncorrected distance visual acuity (UDVA), best corrected visual acuity (BCVA), modulation transfer function cutoff (MTF cutoff), objective scatter index (OSI), strehl ratio (SR), optical interference and patients’ satisfaction were measured in different pupils at three months postoperatively. The associations between decentration and visual quality were analyzed by Spearman correlation. Results: There were no significant differences in decentration, UDVA, BCVA, MTF cutoff, OSI, SR, optical interference and patients’ satisfaction among subgroups. In group A2, the total higher order aberrations (tHOAs) at pupil sizes of 3 mm (P = 0.046), 5 mm (P = 0.014), spherical aberrations at pupil sizes of 3 mm (P = 0.011), 4 mm (P = 0.014), 5 mm (P = 0.000), secondary astigmatism at pupil sizes of 3 mm (P = 0.002), 4 mm (P = 0.005) were higher than in group B2. Compared to group A1, group A2 had higher spherical aberrations at pupil sizes of 4 mm (P = 0.042), 5mm (P = 0.001), 6 mm (P= 0.038), secondary astigmatism at pupil sizes of 3 mm (P = 0.013), 4mm (P = 0.005), 6 mm (P = 0.013). Group B2 has higher coma and secondary astigmatism than group B1 at 6-mm pupil (P = 0.014, P = 0.045). Significant positive correlations were found between spherical aberrations and the decentration of group A1 and A2 at 6-mm pupils. Conclusion: The decentration negatively affected visual quality due to increased tHOAs, spherical aberrations, coma and secondary astigmatism aberrations, the influence become larger with increasing pupil diameter.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3