Wall-to-Lumen Ratio Estimation from Excised Ascending Aortic Aneurysm Rings

Author:

Parikh Shaiv1,Timmermans Finn2,Boxtel Juul van3,Ganizada Berta1,Saraber Pepijn J.M.H.1,Huberts Wouter3,Delhaas Tammo1,Bidar Elham4,Reesink Koen1

Affiliation:

1. Maastricht University

2. Leiden University Medical Center

3. Eindhoven University of Technology

4. Maastricht University Medical Centre (MUMC+)

Abstract

Abstract

Mechanical equilibrium and homeostasis of the vessel wall are dependent on its wall-to-lumen ratio. Ex vivo studies performing wall thickness measurements do not perform measurements on intact rings. Therefore, they lack ex vivo lumen radius, which is necessary to determine the wall-to-lumen ratio. Therefore, in this study we propose an ex vivo wall-to-lumen ratio measurement technique. Our measurements were performed on excised ascending aortic aneurysm rings. We assessed the reliability of our measurement technique through Gage Repeatability and Reproducibility (GRR) analysis, considering both inter- and intra-observer variations. For the samples collected from patient group undergoing ascending aortic repair surgery, our estimates indicate a wall-to-lumen ratio on the order of 0.2, with a GRR coefficient of variation of less than 10%.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370