Comparative Analysis of Ocular Biometrics using Spectral Domain Optical Coherence Tomography with Purkinje Image and Optic Nerve Head Alignments in Mice

Author:

Sze Ying Hon1,Zuo Bing1,Lu Da Qian1,Li King Kit1,Tse Dennis Yan Yin1,Zhao Qian1,Lam Thomas Chuen1

Affiliation:

1. The Hong Kong Polytechnic University

Abstract

Abstract Background Myopia is the leading cause of distance refractive error, in which objects form in front of the retina rather than on the retina itself during emmetropization. Mice is an emerging model for experimental myopia. This study aims to compare ocular biometric measurements with Purkinje image-based and optic nerve head alignment methods of normal eyes in C57BL/6J mice. Methods Ocular dimensions and refractive development were measured on postnatal days P21 (n = 10), P28 (n = 15), and P35 (n = 8). The Purkinje image-based alignment (P1) was determined by a photorefractor and aligned perpendicular to the corneal apex using spectral domain optical coherence tomography (SD-OCT). In comparison to the optic nerve head (ONH) alignment due to the lack of fovea in mice retina. Variance analysis, regression analysis and Bland‒Altman analysis were performed to compare differences between alignment methods and replication by another operator. Results Mice developed hyperopic ametropia under normal visual conditions. The photorefractor measured a technical variation of 3.9 D (95% CI, n = 170, triplicates). Bland-Altman analysis revealed a shorter (mean ± SD) axial length (-26.4 ± 18.1 µm) and vitreous chamber depth (-39.9 ± 25.4 µm) in Purkinje image-based alignment. Significant difference in the relative growing trend in VCD (linear regression, p = 0.02), relatively stable and shortening when measured with ONH alignment from postnatal age 21 to 35 days. Conclusions SD-OCT allowed precise in-vivo ocular dimension measurement and segmentation. A significantly shorter AL and VCD were observed in Purkinje image based (P1) alignment compared to ONH method, highlighting the importance of alignment methods in optical based technique that may introduce false positive axial elongation in myopia research. Axial length has better consistency over VCD for the evaluation of axial elongation.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3