The Flex-it® Articulated Stylet Does Not Shorten Intubation Duration During Videolaryngoscopy Compared to the GlideRite® Rigid Stylet in Patients Wearing a Semi-rigid Cervical Collar: A Randomized Controlled Trial

Author:

Nguyen John Viet1,Drolet Pierre2,Bélanger Marie-Ève3,Issa Rami1,Richebé Philippe1,Godin Nadia3,Zaphiratos Valerie1,Godbout-Simard Cédric1,Bussières Jean S4,Georgescu Mihai2,Tanoubi Issam2

Affiliation:

1. Université de Montréal

2. Centre d'Apprentissage des Attitudes et Habiletés Cliniques (CAAHC), Université de Montréal

3. Maisonneuve-Rosemont Hospital, University of Montréal

4. Institut universitaire de cardiologie et de pneumologie de Québec (IUCPQ)

Abstract

Abstract

Introduction Compared to the GlideRite® rigid stylet used with the GlideScope® and its hyperangulated blade, the Flex-it® stylet permits a dynamic orientation of the endotracheal tube toward the glottic aperture. Our study compared the GlideRite stylet and Flex-it stylet on GlideScope intubation durations in patients wearing a semi-rigid cervical collar, simulating conditions of cervical instability. Methods Our institutional research ethics board approved the study protocol (Hôpital Maisonneuve-Rosemont IRB#14013) for this single-centre randomized controlled trial on 12/05/2014. Eighty patients between 18 and 70 years old were randomized into one of two interventions: intubation with GlideScope + GlideRite stylet (GlideRite) or intubation with GlideScope + Flex-it stylet (Flex-it). We used a hyperangulated blade, size 4. All included patients provided written consent, had American Society of Anesthesiologists (ASA) physical status I or II, and did not exhibit any difficult intubation criteria or known cervical spine anomaly. Following induction of anesthesia, a Philadelphia® semi-rigid cervical collar was installed to simulate conditions associated with cervical instability. One of the three anesthesiologists participating in the study performed the intubation. The primary endpoint was intubation duration in seconds, from the beginning of the laryngoscopy until detection of expired CO2. Secondary outcomes were endotracheal tube handling duration in seconds, intubation failure, Intubation Difficulty Score, and ease of stylet removal. Variations in blood pressure, heart rate, O2 saturation during intubation, postoperative hoarseness, and sore throat intensity were also compared between the interventions. Results Intubation was longer when using Flex-it vs. GlideRite (sec, Median [quartiles]), 71 [50-84] vs. 48 [39-60], P = .006). Kaplan-Meier curves showed that at 1 min, 20% of Flex-it patients were intubated vs. only 20% of GlideRite patients. The endotracheal tube (ETT) handling duration (sec, Median [quartiles]) was longer with Flex-it than with GlideRite, with 48 [33-66] vs. 34 [25-39], P = .007. The percent of failures was significantly higher with Flex-it (13/38, 32.5%) compared to GlideRite (1/38, 2.5%), P< .001. The Intubation Difficulty Scale score was significantly higher for Flex-it, with median [quartiles] of 6[5-7], compared to 2[2-5] for GlideRite, P< .001. There were no blood stains on the ETT or desaturations in either intervention. Ease of stylet removal, hoarseness, sore throat, blood pressure and heart rate measurements, and O2 saturation after intubation were not different between the interventions. Conclusion Videolaryngoscopy intubation using the Flex-it stylet was slower, more difficult, and had more failures than the GlideRite stylet in patients with simulated cervical instability wearing a semi-rigid cervical collar.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3