Progressive resolution optimizer (PRO) predominates over photon optimizer (PO) in sparing of spinal cord for spine SABR VMAT plans

Author:

Son Sangjun1,Park So-Yeon2

Affiliation:

1. Seoul National University Hospital

2. Veterans Health Service Medical Center

Abstract

Abstract Background: we assessed the performance of the optimization algorithms by comparing volumetric modulated arc therapy generated by a progressive resolution optimized (VMATPRO) and photon optimizer (VMATPO) in terms of plan quality, MU reduction, sparing of the spinal cord (or cauda equina), and plan complexity. Methods: Fifty-seven patients who received spine stereotactic ablative radiotherapy (SABR) with tumors located in the cervical, thoracic, and lumbar spine were retrospectively selected. For each patient, VMATPRO and VMATPO with two full arcs were generated with using the PRO and PO algorithms. For dosimetric evaluation, the dose-volumetric (DV) parameters of the planning target volume (PTV), organs at risk (OARs), the corresponding planning organs at risk (PRV), and 1.5-cm ring structure surrounding the PTV (Ring1.5 cm) were calculate for all VMAT plans. The total number of monitor units (MUs) and the modulation complexity score for the VMAT (MCSv) were compared. To investigate the correlations of OAR sparing to plan complexity, Pearson’s and Spearman’s correlation tests were conducted between the two algorithms (PO – PRO, denoted as Δ) in the DV parameters for normal tissues, total MUs, and MCSv. Results: For the PTVs, Target conformity and dose homogeneity in the PTVs of VMATPRO were better than those of VMATPO with statistical significance. For the spinal cords (or cauda equine) and corresponding PRVs, all of the DV parameters for VMATPRO were markedly lower than those for VMATPO, with statistical significance (all p < 0.0001). Among them, the difference in the maximum dose to the spinal cord between VMATPRO and VMATPO was remarkable (9.04 Gy vs 11.08 Gy with p < 0.0001). For Ring1.5 cm, no significant difference in V115% for VMATPRO and VMATPO was observed. Conclusions: The use of VMATPRO resulted in coverage and uniformity of dose to the PTV, as well as OARs sparing, compared with that of VMATPO for cervical, thoracic, and lumbar spine SABR. Better dosimetric plan quality generated by the PRO algorithm was observed to result in higher total MUs and plan complexity. Therefore, careful evaluation of its deliverability should be performed with caution during the routine use of the PRO algorithm.

Publisher

Research Square Platform LLC

Reference25 articles.

1. Spinal metastases: the obvious, the occult, and the impostors;Wong DA;Spine (Phila Pa 1976),1990

2. Ecker RD, Endo T, Wetjen NM, Krauss WE. Diagnosis and treatment of vertebral column metastases. Mayo Clin Proc. 2005;80(9):1177-86.

3. Cancer to bone: a fatal attraction;Weilbaecher KN;Nat Rev Cancer,2011

4. In-house developed surface-guided repositioning and monitoring system to complement in-room patient positioning system for spine radiosurgery;Kim KH;Prog Med Phys,2021

5. Radiotherapy or surgery for spine metastases?;Zaikova O;Acta Orthop,2011

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3