Endoscopic ultrasound-guided tissue acquisition using Fork-tip needle for subepithelial lesions: A single-center validation study

Author:

Watanabe Masafumi1,Okuwaki Kosuke1,Iwai Tomohisa1,Kida Mitsuhiro1,Imaizumi Hiroshi1,Adachi Kai1,Tamaki Akihiro1,Ishizaki Junro1,Hanaoka Taro1,Kusano Chika1

Affiliation:

1. Kitasato University School of Medicine

Abstract

Abstract Background The cutoff value for stereomicroscopic on-site evaluation (SOSE) in endoscopic ultrasound-guided tissue acquisition (EUS-TA) has high diagnostic sensitivity when a Franseen needle is employed for upper gastrointestinal subepithelial lesions (SELs) (stereomicroscopically visible white core [SVWC] ≥ 4 mm). Aim We aimed to determine whether high diagnostic sensitivity could be obtained when EUS-TA was performed using a Fork-tip needle. Methods Twenty-one patients were prospectively registered. Patients underwent EUS-TA using a Fork-tip needle for upper gastrointestinal SELs at Kitasato University Hospital between January and November 2022. Punctures were made twice using the needle, and SOSE was conducted for each specimen. Blood and physical examination were performed to assess adverse events. Pathological diagnosis was made using hematoxylin and eosin-stained sections and immunohistochemical staining. Statistical comparisons were completed using Fisher’s exact tests. Results The diagnostic rate of EUS-TA was 100% (21/21 cases). The final diagnosis was gastrointestinal stromal tumor in 17 (81.0%) and leiomyoma in 4 (19.0%) patients. SOSE was conducted on all 42 punctures, and the tissue sampling rate was 100% (42/42 punctures). Specimens with SVWC ≥ 4 mm were collected in 97.6% punctures (41/42 punctures) and the diagnostic sensitivity for these specimens was 100% (41/41 punctures), which is significantly higher (p < 0.0238) compared to the absence of cutoff value (diagnostic sensitivity of 0%). No EUS-TA-related adverse events occurred. Conclusions EUS-TA combined with SOSE for upper gastrointestinal SEL using a fork-tip needle had a high diagnostic rate, and the cutoff value of SVWC ≥ 4 mm had high diagnostic sensitivity.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3