In Vitro Hemodynamic Performance of a Blood Pump for Self-powered Venous Assist in Univentricular Hearts

Author:

Rasooli Reza1,Holmstrom Henrik2,Giljarhus Knut Erik Teigen1,Jolma Ingunn Westvik1,Vinningland Jan Ludvig3,de Lange Charlotte4,Brun Henrik2,Hiorth Aksel1

Affiliation:

1. University of Stavanger

2. Oslo University Hospital

3. Norwegian Research Centre

4. Sahlgrenska University Hospital

Abstract

Abstract Univentricular heart anomalies represent a group of severe congenital heart defects necessitating early surgical intervention in infancy. The Fontan procedure, the final stage of single-ventricle palliation, establishes a serial connection between systemic and pulmonary circulation by channeling venous return to the lungs. The absence of the subpulmonary ventricle in this peculiar circulation progressively eventuates in failure, primarily due to chronic elevation in inferior vena cava (IVC) pressure. This study experimentally validates the effectiveness of an intracorporeally-powered venous ejector pump (VEP) in reducing IVC pressure in Fontan patients. The VEP exploits a fraction of aortic flow to create a jet-venturi effect for the IVC, negating the external power requirement and driveline infections. A multi-scale in-vitro Fontan mock-up circulation loop is developed and the impact of VEP design parameters and physiological conditions is assessed using both idealized and patient-specific total cavopulmonary connection (TCPC) phantoms. The VEP performance in reducing IVC pressure exhibited an inverse relationship with the cardiac output and extra-cardiac conduit (ECC) size and a proportional relationship with the transpulmonary pressure gradient (TPG) and mean arterial pressure (MAP). The ideal VEP with fail-safe features provided an IVC pressure drop of 1.82 ± 0.49, 2.45 ± 0.54, and 3.12 ± 0.43 mm Hg for TPG values of 6, 8, and 10 mm Hg, respectively, averaged over all ECC sizes and cardiac outputs. Furthermore, the arterial oxygen saturation was consistently maintained above 85% in all conditions. These results emphasize the potential utility of the VEP to mitigate elevated venous pressure in Fontan patients.

Publisher

Research Square Platform LLC

Reference66 articles.

1. Birth prevalence of congenital heart disease worldwide: a systematic review and meta-analysis;Linde D;Journal of the American College of Cardiology,2011

2. Changing landscape of congenital heart disease;Bouma BJ;Circulation research,2017

3. Surgical repair of tricuspid atresia;Fontan F;Thorax,1971

4. An operation for the correction of tricuspid atresia;Kreutzer G;The Journal of thoracic and cardiovascular surgery,1973

5. The Fontan circulation: what have we learned? What to expect?;Leval MR;Pediatric cardiology,1998

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3