Abstract

Abstract Background The EVA Nexus system offers several technical improvements over its predecessor. The newly designed Aveta cannula system for vitrectomy surgery avoids the need for removal of the valve from the infusion cannula. The chamfered leading edge of the cannula also reduces the insertion force needed. The new EquiPhaco needles in combination with SmartIOP provide excellent anterior chamber stability during phaco-emulsification surgery, enabling to work at lower infusion pressures, and the multiburst phaco mode allows easier removal of hard cataracts. The system offers a secondary active infusion line for independent control of pressure to the anterior and posterior chambers, monitoring of flow rate/reflux and warning of infusion bottle emptying. This study evaluated whether these technical improvements result in improved surgical safety. Methods In total, 250 eyes that underwent vitrectomy (53%) or phaco-vitrectomy (47%) using the EVA Nexus systemwere prospectively included. The occurrence of intraoperative adverse events was compared to that of historically operated eyes using the EVA system. Trial Registration number Clinicaltrials.gov: NCT05229094 Data 22/5/2021. Results The average age of the patients was 63 years. A total of 33% of the patients were operated on for retinal detachment, 17% for macular pucker, 11% for treating floaters, 9% for removing silicone oil, 8% for macular hole repair and 22% for other diseases. In 75% of surgeries, 23 G instruments were used, and 27 G instruments were used in 25% of cases. Device issues that occurred included priming cycle issues (n=4), eye pressure stability problems (n=6) and vitrectome performance issues (n=1), all of which in the first 100 patients who were included and were fixed with software updates. The frequency of surgical complications in the anterior segment was lower than that in the historically recorded surgical reports. Intraoperativeevents in the posterior segment included hemorrhage from retinal vessels, choroidal hematoma, iatrogenic retinal damage/tear, and subchoroidal infusion. Again, these events occurred rarely and less frequently than in the historical surgical reports. Conclusions The EVA Nexus provides a surgical platform that reduces the incidence of intraoperative adverse events and iatrogenic complications in both anterior and posterior segment surgery. This could increase surgical safety during cataract and vitrectomy surgery.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3