Analysis of the Visual Function With the Continuous Transitional Focus Intraocular Lens Precizon Presbyopic

Author:

León-Ibáñez Luis1,Piñero David Pablo2

Affiliation:

1. Clínica Oftalmológica MOAT

2. University of Alicante

Abstract

Abstract

Purpose To evaluate the clinical outcomes of a refractive multi-segmented continuous transitional focus intraocular lens (IOL), analyzing the potential influence of patient pupil dynamics on these outcomes\. Methods Retrospective consecutive case series study enrolling 40 eyes (20 patients, 47–81 years) implanted with the Precizon Presbyopic IOL (Ophtec BV). The following clinical outcomes were analyzed during a mean follow-up of 12.1 months (2–24 months): visual acuity, refraction, contrast sensitivity (CS) under photopic and mesopic conditions, binocular defocus curve and evaluation of the perception of disturbing visual symptoms with a validated questionnaire. Results Mean binocular uncorrected distance (UDVA), distance-corrected intermediate (DCIVA), uncorrected near (UNVA) and distance-corrected near visual acuities (DCNVA) were − 0.09 ± 0.07, 0.04 ± 0.05, 0.17 ± 0.12, and 0.15 ± 0.10 logMAR, respectively. In the binocular defocus curve, mean distance-corrected visual acuity was over 0.20 logMAR for defocus levels from + 1.50 to -3.00 D. No significant correlations of photopic pupil diameter were found with any postoperative visual acuity data (-0.165 ≤ r ≤ 0.192, p ≥ 0.235). Moderate correlations of mesopic pupil size were found with visual acuities for the defocus levels of -2.50 (r = 0.454, p = 0.003), -3.00 (r = 0.609, p < 0.001), -3.50 (r = 0.519, p < 0.001), and − 4.00 D (r = 0.403, p = 0.010). Only significant differences were found between mesopic and photopic CS for 12 cycles/degree (p = 0.010). No cases of severe glare or halos were detected. In contrast, 10% of patients referred the severe perception of starbursts postoperatively. Full spectacle independence was referred by almost all patients (90%). Conclusions The IOL demonstrates effective visual restoration at various distances, characterized by high levels of visual quality and minimal dependence on pupil dynamics.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3