Evaluation of Tear Film Break-Up Time after First-Time Wearing of Verofilcon A Silicone Hydrogel, 1-day Disposable Contact Lenses: FTVeA study

Author:

Misu Naoko1,Mimura Tatsuya1,Noma Hidetaka2,Kawashima Makoto1,Mizuno Yoshinobu1,Yamaguchi Masao3,Shinbo Koichiro3,Inoue Yuji1

Affiliation:

1. Teikyo University School of Medicine

2. Tokyo Medical University

3. Nerima Station West Eye Clinic

Abstract

Abstract Purpose The dryness and discomfort associated with soft contact lenses (SCLs) prevent their continued use. Recently, verofilcon A, a new daily disposable silicone hydrogel material SCL, was introduced, which has a high-water content (surface water content of 80% or more) that overcomes the low water content drawback of silicone hydrogels. Furthermore, the surface treatment with SMARTSURFACE® Technology is expected to improve water-wettability during SCL wear. In this study, we evaluated the non-invasive tear break-up time (NIBUT) and comfort level in individuals wearing verofilcon A SCL for the first time. Methods We enrolled 42 first-time SCL wearers, comprising 84 eyes. NIBUT was measured using the DR-1α® dry eye observation device, at the state of the naked eye before SCL wear (baseline), and at 1 and 4 weeks after the first SCL wear. Additionally, we conducted a questionnaire survey during the fourth week to assess the comfort level (0–10) of SCL wear. Results The NIBUT values were significantly higher at 1 week (10.8 ± 2.2 s, p < 0.01) and 4 weeks (11.4 ± 2.2 s, p < 0.01) after the first SCL wear than those at baseline (5.9 ± 2.0 s). Comfort level in SCL use was significantly higher at 1 week (9.0 ± 1.1, p < 0.01) and 4 weeks (8.7 ± 1.2, p < 0.01) than that at baseline (7.8 ± 1.8), and this level was higher regardless of the baseline NIBUT value. Conclusion Prolonged BUT and increased comfort levels were observed in individuals wearing verofilcon A SCLs. Improvement in tear fluid retention was found to alleviate dry eye and discomfort, suggesting that verofilcon A may be a beneficial introductory lens for the first-time SCl wearers. Trial registration number and date: UMIN registration numbers: UMIN000041107 (July/15/2020) and UMIN000042265 (October/28/2020)

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3