Effect of Peritoneal Dialysate on Bioelectrical Impedance Analysis Variability in Pediatric Patients Receiving Peritoneal Dialysis

Author:

Prukngampun Natthida1,Densupsoontorn Narumon1,Pattaragarn Anirut1,Pooliam Julaporn1,Tinnabut Intraparch1,Sumboonnanonda Achra1,Supavekin Suroj1,Piyaphanee Nuntawan1,Lomjansook Kraisoon1,Thunsiribuddhichai Yanarin1,Chaiyapak Thanaporn2ORCID

Affiliation:

1. Mahidol University Faculty of Medicine Siriraj Hospital

2. Mahidol University Faculty of Medicine Siriraj Hospital Department of Pediatrics

Abstract

Abstract Background: Previous adult studies have yielded conflicting results regarding whether the presence (D+) or absence (D-) of peritoneal dialysate affects the accuracy of bioelectrical impedance analysis (BIA) measurements. The aim of this study was to investigate whether the accuracy of BIA data varies between D+ and D- measurements in children. Methods: This cross-sectional study recruited chronic kidney disease stage 5 patients aged 3 to 18 years who received peritoneal dialysis. Body composition was assessed by multifrequency BIA, and values were compared between D+ and D- measurements using the intraclass correlation coefficient (ICC) and Bland-Altman plots. Results: Fifty paired BIA measurements were collected from 18 patients with a mean age of 13.6±4.1 years and a mean dialysate fill volume of 1,006±239.7 ml/m2. Almost all BIA parameters exhibited excellent correlations between D+ and D- measurements (ICC values=0.954-0.998). There was a trend of increased fluid status, including extracellular water, edema index, and overhydration, in D+ measurements, with mean differences (95% CIs) of 0.5 (0.4-0.6) L, 0.002 (0.001-0.002), and 0.1 (0.1-0.2) L, respectively. Soft lean mass and fat-free mass were higher in D+ measurements, with mean differences (95% CIs) of 1.4 (1.2-1.6), and 1.6 (1.4-1.8) kg, respectively. The Bland-Altman plots showed low variability in BIA parameters, as indicated by the narrow 95% limits of agreement between D+ and D- measurements. Conclusions: Almost all BIA parameters exhibited excellent correlations and low variability between D+ and D- measurements. We recommend that BIA measurements be collected from children regardless of the presence of peritoneal dialysate.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3