Calculated and measured radiation dose in water for the low energy Xoft Axxent eBT X-ray source

Author:

CAN SUMEYRA1,ATILLA OZGE1,KARACETIN DIDEM1

Affiliation:

1. Başakşehir Çam and Sakura City Hospital

Abstract

Abstract Purpose This study aims at evaluating the functionality of different dose fractions for the Xoft Axxent electronic brachytherapy (eBT) system and analyzing the system in terms of radiation dosimetry in water. Materials and Methods Different dose fraction schemes for the Xoft Axxent eBT system were calculated for different balloon applicator volumes based on dwell positions and dwell times. EBT-XD Gafchromic film was calibrated at 6MV photon energy and a calibration curve was devised for it which were used for dosimetric measurements. In the first phase, a balloon applicator filled with 0.9% isotonic sodium chloride (NaCl) solution was used for dosimetric measurements with the ability to deliver 20 Gy, 16 Gy, 10 Gy radiation dose in one fraction. Afterward, the balloon applicator was filled with water and the same measurements were performed. Finally, the balloon applicator was irradiated at different distances in the water tank and the simulation of dose distribution in the water was obtained so as to analyze the dose distribution in the tissue. Results At the time the balloon applicator was filled with 0.9% NaCl solution, the absorbed dose was approximately 23 Gy for 30 cc balloon volume, 22.8 Gy for 35 cc and 22 Gy for 40 cc balloon volume. On the other side, when the applicator was filled with water, the absorbed dose is approximately 20.5 Gy for 30 cc, 21 Gy for 35 cc, and 20,7 Gy for 40 cc balloon applicator. As a result, provided the balloon applicator was filled with water, the difference between the planned dose and the absorbed dose was ~ 2% for 30 cc, ~ 5% for 35 cc and ~ 3,5% for 40 cc. Accordingly, the fact that 0.9% NaCl solution caused an increase in the absorbed dose from the photoelectric effect was determine. Finally, the absorbed dose at a distance of 1 cm from the applicator surface was measured as 9.63 Gy which was obtained in accordance with the manufacturer’s criteria. Conclusion Different dose fraction schemes were created in the Xoft Axxent eBT system based on the standard atlas plan. In addition, this study shows that photoelectric effect in low energy photons increases the difference between the planned dose and the absorbed dose depending on the effective atomic number. By measuring the dose distributions at different distances from the balloon applicator surface, the absorbed dose in tissue equivalent medium was determined and the dose distribution characteristics was simulated.

Publisher

Research Square Platform LLC

Reference32 articles.

1. The role of intraoperative radiotherapy in solid tumors;Skandarajah A;Annals of surgical oncology,2009

2. Present status and future directions of intraoperative radiotherapy;Debenham BJ;The lancet oncology,2013

3. Alternative techniques of intraoperative radiotherapy;Ellis RJ;European Journal of Surgical Oncology,2000

4. Gatzemeier W, Orecchia R, Gatti G, Intra M, Veronesi U. Intraoperative radiotherapy (IORT) in treatment of breast carcinoma–a new therapeutic alternative within the scope of breast-saving therapy? Current status and future prospects. Report of experiences from the European Institute of Oncology (EIO), Mailand. Strahlentherapie und Onkologie: Organ der Deutschen Rontgengesellschaft[et al]. 2001;177(7):330–7.

5. Long-term survivors using intraoperative radiotherapy for recurrent gynecologic malignancies;Tran PT;International Journal of Radiation Oncology* Biology* Physics,2007

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3