Microbial volatile organic compounds measured in the air of a waste sorting plant and a university by thermal desorption-gas chromatography-tandem mass spectrometry
Author:
Tabbal Sarah1, Aroussi Badr El1, Haddad Sami1, Marchand Geneviève2
Affiliation:
1. Centre de recherche en santé publique (CReSP) 2. Institut de recherche Robert-Sauvé en santé et en sécurité du travail (IRSST)
Abstract
Abstract
In recyclable waste management facilities, several contaminants, mainly bioaerosols and microorganisms, can be released and cause potential adverse health effects. Given that microbial volatile organic compounds (mVOCs) are metabolites developed by molds and since they can be considered as potential biomarkers of mold exposure, their concentrations in ambient air were monitored at a recyclable waste sorting plant (WSP) and a university campus (UC) serving as control environment for comparison. A recently developed analytical method was used and optimised for the detection of 21 selected mVOCs in real conditions. The impact of mVOCs sampling duration, period of the day and variability of their concentrations between different workstations at both sites, were studied. At UC, only 3 mVOCs were detected in comparison with 13 mVOCs at the WSP. The optimal sampling duration of 2 hours was chosen to increase the sensitivity of the method. Statistical tests showed no significant difference in concentration for the detected mVOCs at WSP for different period of the day whereas an increase in concentrations for ethyl acetate was observed at UC. At WSP, the highest concentrations were measured at the pre-sorting room, followed by the sorting room, the optic sorting room and the lowest concentrations were measured at the waste reception area. This study allows the optimisation of the mVOCs sampling method, the comparison of the mVOC profils between contaminated and non-contaminated workplaces and the recommendation for mVOCs with better potential as biomarkers of mold exposure.
Publisher
Springer Science and Business Media LLC
Reference65 articles.
1. Agency for toxic substances and disease registry (ATSDR), (1992). Toxicological profile for 2-butanone. Atlanta, GA: U.S. Department of Health and Human Services, Public Health Service. 2. Araki, A., Kawai, T., Eitaki, Y., Kanazawa, A., Morimoto, K., Nakayama, K., Shibata, E., Tanaka, M., Takigawa, T., Yoshimura, T., Chikara, H., Saijo, Y., & Kishi, R. (2010). Relationship between selected indoor volatile organic compounds, so-called microbial VOC, and the prevalence of mucous membrane symptoms in single family homes. Science of The Total Environment, 408(10), 2208–2215. https://doi.org/10.1016/j.scitotenv.2010.02.012 3. Biasioli, F., Gasperi, F., Odorizzi, G., Aprea, E., Mott, D., Marini, F., Autiero, G., Rotondo, G., & Märk, T. D. (2004). PTR-MS monitoring of odour emissions from composting plants. International Journal of Mass Spectrometry, 239(2–3), 103. 4. Borchers, A. T., Chang, C., & Eric Gershwin, M. (2017). Mold and Human Health: A Reality Check. Clinical Reviews in Allergy & Immunology, 52(3), 305–322. https://doi.org/10.1007/s12016-017-8601-z 5. Brodhagen, M., Tsitsigiannis, D. I., Hornung, E., Goebel, C., Feussner, I., & Keller, N. P. (2008). Reciprocal oxylipin-mediated cross-talk in the Aspergillus–seed pathosystem. Molecular Microbiology, 67(2), 378–391. https://doi.org/10.1111/j.1365-2958.2007.06045.x
|
|