The diagnostic accuracy of lung ultrasound to determine PiCCO-derived extravascular lung water in invasively ventilated patients with COVID-19 ARDS

Author:

Atmowihardjo Leila N.1,Schippers Job R.2,Haaksma Mark E.3,Smit Marry R.1,Bogaard Harm J.2,Heunks Leo4,Juffermans Nicole P.5,Schultz Marcus J.3,Endeman Henrik4,Velzen Patricia van6,Tuinman Pieter R.3,Aman Jurjan2,Bos Lieuwe D. J.1

Affiliation:

1. Amsterdam UMC, location AMC, Intensive Care

2. Amsterdam UMC, location VUMC, Pulmonology

3. Amsterdam UMC, location VUMC, Intensive Care

4. Erasmus University Medical Center, Intensive Care

5. Onze Lieve Vrouwe Gasthuis, Intensive Care

6. Dijklander hospital location Purmerend, Intensive Care

Abstract

Abstract Background: Lung ultrasound (LUS) is a non-invasive method to detect and quantify pulmonary edema. However, it remains uncertain how components of the LUS examination should be aggregated into a score for quantifying pulmonary edema. We examined the diagnostic accuracy of various LUS scores with the extravascular lung water index (EVLWi) assessed with PiCCO in patients with moderate-to-severe COVID-19 ARDS. Methods: In this predefined secondary analysis of a multicenter randomized-controlled trial (InventCOVID), patients were included within 48h after intubation and underwent LUS and EVLWi measurement at two time points (first and fourth study day). EVLWi and ∆EVLWi were used as reference standard. Two 12-region scores (global LUS and LUS-ARDS), an 8-region anterior-lateral score and a 4-region B-line score were used as index tests. Pearson correlation was performed and the area under the receiver operating characteristics curve (AUROCC) for severe pulmonary edema (EVLWi>15mL/kg) was calculated. Results: 26 of 30 patients (87%) had complete LUS and EVLWi measurements at time point 1 and 24 of 29 patients (83%) at time point 2. The global LUS (r=0.54), LUS-ARDS (r=0.58) and anterior-lateral score (r=0.54) were significantly correlated with EVLWi, while the B-line score was not (r=0.32). ∆global LUS (r=0.49) and ∆anterior-lateral LUS (r=0.52) were significantly correlated with ∆EVLWi, while correlation of ∆LUS-ARDS (r=0.43) and ∆B-lines (r=0.32) did not reach statistical significance. AUROCC for EVLWi>15ml/kg was 0.73 for the global LUS, 0.79 for the anterior-lateral and 0.85 for the LUS-ARDS score. Conclusions: The global LUS, LUS-ARDS and antero-lateral score can quantify PiCCO-derived pulmonary edema measurements in COVID-19 ARDS. The LUS-ARDS score showed the highest diagnostic accuracy for severe pulmonary edema. Trial registration: ClinicalTrials.gov identifier NCT04794088, registered on 11 March 2021. European Clinical Trials Database number 2020-005447-23.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3