Transcutaneous carbon dioxide measurements in patients undergoing retroperitoneoscopic urologic surgery: A prospective observational study

Author:

Liu Yang1,Li Nan1,Kong Qiuyue1,Huang Shaokang1,Wang Xian2,Yang Chun1,Liu Cunming1,Ding Zhengnian1,Liu Shijiang1

Affiliation:

1. The First Affiliated Hospital of Nanjing Medical University

2. Nanjing Medical University

Abstract

Abstract Purpose: The aim of the current study was to investigate the accuracy of transcutaneous CO2 pressure (PTCCO2) monitoring and the correlation between it and arterial CO2 pressure (PaCO2), so as to determine PaCO2 in patients undergoing retroperitoneoscopic urologic surgery. Methods: 50 patients undergoing retroperitoneoscopic urologic surgery were enrolled in this study. PaCO2, end-tidal carbon dioxide partial pressure (PETCO2), and PTCCO2 values were measured at 4 time points: before pneumoperitoneum, 30 mins, 60 mins and 90 mins after pneumoperitoneum, respectively. The differences of PaCO2 PETCO2 and PaCO2 - PTCCO2 were calculated. Paired t test, Bland–Altman method, correlation and regression analysis, as well as Fisher’s exact test were employed for the data analysis. Results: Totally 157 samples were obtained. The mean (SD) of PaCO2, PETCO2 and PTCCO2 were 55.5 (7.2) mmHg, 42.3 (5.2) mmHg and 51.9 (84) mmHg, respectively. The absolute difference of PaCO2-PETCO2 was 13.20 ± 4.43 mmHg and 4.35 ± 2.56 mmHg for PaCO2-PTCCO2 (P < 0.0001). And the correlation coefficient (r) between PaCO2 and PETCO2 was 0.79 (r2 = 0.62, P < 0.0001) , whereas that value between PaCO2 and PTCCO2 was 0.91 (r2 = 0.83, P < 0.0001). Meanwhile, the linear regression between PaCO2 and PETCO2 was PETCO2 = 0.60×PaCO2+9.10 (P < 0.0001), whilst the counterpart between PaCO2 and PTCCO2 was PTCCO2 = 1.07×PaCO2-7.30 (P < 0.0001). The 95% limits of agreement (LOA) of PaCO2 versus PETCO2 was 4.53 to 21.88 mmHg and -3.18 to 10.48 mmHg for PaCO2 versus PTCCO2. Conclusion: PTCCO2 monitoring provided greater accuracy to estimate PaCO2 in patients undergoing retroperitoneoscopic urologic surgery as compared to PETCO2 .

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3