Affiliation:
1. University of Science and Technology of China
2. Chinese Academy of Medical Sciences, Peking Union Medical College Hospital
Abstract
Abstract
Objective:
Anatomical variations existing in cervical cancer radiotherapy treatment can be monitored by cone-beam computed tomography (CBCT) images. Deformable image registration (DIR) from planning CT (pCT) to CBCT images and synthetic CT (sCT) image generation based on CBCT are two methods for improving the quality of CBCT images. This study aims to compare the accuracy of these two approaches geometrically and dosimetrically in cervical cancer radiotherapy.
Methods:
In this study, 40 paired pCT-CBCT images were collected to evaluate the accuracy of DIR and sCT generation. The DIR method was based on a 3D multistage registration network that was trained with 150 paired pCT-CBCT images, and the sCT generation method was performed based on a 2D cycle-consistent adversarial network (CycleGAN) with 6000 paired pCT-CBCT slices for training. Then, the doses were recalculated with the CBCT, pCT, deformed pCT (dpCT) and sCT images by a GPU-based Monte Carlo dose code, ArcherQA, to obtain DoseCBCT, DosepCT, DosedpCT and DosesCT. Organs at risk (OARs) included small intestine, rectum, bladder, spinal cord, femoral heads and bone marrow, CBCT and pCT contours were delineated manually, dpCT contours were propagated through deformation vector fields, sCT contours were auto-segmented and corrected manually.
Results:
The global gamma pass rate of DosesCT and DosedpCT was 99.66% ± 0.34%, while that of DoseCBCT and DosedpCT was 85.92% ± 7.56% at the 1%/1 mm criterion and a low-dose threshold of 10%. Based on DosedpCT as uniform dose distribution, there were comparable errors in femoral heads and bone marrow for the dpCT and sCT contours compared with CBCT contours, while sCT contours had lower errors in small intestine, rectum, bladder and spinal cord, especially for those with large volume difference of pCT and CBCT.
Conclusions:
For cervical cancer radiotherapy, the DIR method and sCT generation could produce similar precise dose distributions, but sCT contours had higher accuracy when the difference in planning CT and CBCT was large.
Publisher
Research Square Platform LLC
Reference35 articles.
1. Variability of four-dimensional computed tomography patient models;Sonke JJ;Int J Radiat Oncol Biol Phys,2008
2. Intra thoracic anatomical changes in lung cancer patients during the course of radiotherapy;Kwint M;Radiother Oncol,2014
3. Accuracy of radiotherapy dose calculations based on cone-beam CT: comparison of deformable registration and image correction based methods;Marchant TE;Phys Med Biol,2018
4. Method for converting cone-beam CT values into Hounsfield units for radiation treatment planning;Abe T;Int J Med Phys Clin Eng Rad Oncol,2017
5. Marchant TE, Joshi KD, Moore CJ. Shading correction for cone-beam CT in radiotherapy: validation of dose calculation accuracy using clinical images. In Proc. SPIE 10132, Medical Imaging 2017: Physics of Medical Imaging. 2017.10132 101320J1-101320J11.