The Added Value of Low-Dose CT to SPECT V/Q Scan in Diagnosis of Pulmonary Embolism

Author:

Mohamed Yahya Ali1,Ahmed Tawakol1,El_Sayed Yasser Ahmed1,Taymour Takeya A.1,Badawy Ahmed1

Affiliation:

1. Faculty of Medicine, Cairo University

Abstract

Abstract Background The purpose of this study was to compare the known V/Q images that carried out as traditional planar scintigraphy using Prospective Investigation of Pulmonary Embolism Diagnosis (modified PIOPED II) interpretation criteria to the potential benefit and diagnostic ability of combining Low Dose-CT to perfusion SPECT, without contrast agent administration, for the detection of pulmonary embolism (PE). Material and methods Eighty-one patients presented with symptoms suggestive of pulmonary embolism. In all 81 cases, planar perfusion lung scans with SPECT/CT were conducted, whereas complementing planar ventilation was performed in 27 cases. SPECT/CT findings in all cases made the diagnosis based on the segmental and sub-segmental perfusion defects regarding the 2009 EANM guideline for PE diagnosis. V/Q scans were compared to SPECT/CT findings for 27 patients according to Modified PIOPED II. Results Among the normal perfusion cases with no defect by planar scan, 48 patients (59.3%) still entirely normal on SPECT. SPECT add small segmental defects in 16 patients (19.8%), 2 patients of them converted from low to high probability for PE. Nevertheless, the increase in the number of defects discovered throughout the whole research group when compared to planar scan indicates that SPECT has added value in defect detection. In the diagnosis of PE, lung perfusion scintigraphy paired with CT conducted by hybrid SPECT/CT gamma cameras offers a good diagnostic effectiveness. SPECT/CT was shown to be more accurate than planar scintigraphy, with a sensitivity of 100.0%, specificity of 85.7%, and accuracy of 92.6%. Conclusions Including low-dose CT in lung perfusion SPECT demonstrated increased diagnostic utility of perfusion scan with enhanced negative predictive value to rule out PE. The use of low-dose CT improves the test's diagnostic yield by providing information on other diseases that explain the presenting symptoms. Specificity is increased, allowing a single imaging technique to detect PE with high accuracy while also ruling out other possible causes of chest discomfort and SOB.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3