Effect of lung volume preservation during spontaneous breathing trial on successful extubation among patients receiving mechanical ventilation. Study protocol for a multi-center clinical trial.

Author:

Subira Carles1ORCID,Rognoni Gina1,Baquerizo Herbert1,García Carolina2,Cabañes Sara3,Torre Maria de la4,Quevedo Beatriz5,Pedrós Cristina6,Tizón Ana I.7,Murillo Natalia8,Parro Laura9,Eiras Fernando10,Rialp Gemma11,Altaba Susana12,González-Castro Alejandro13,Pacheco Andrés F.14,Bayoumi Pablo15,Medrano Norma16,Vallverdú Imma17,Higón Áurea18,Navarro María D.19,Falcón Alirio20,Keough Elena21,Arizo David22,Martínez Juan F.23,Durán Núria24,Rodríguez Raquel25,Popoviciu-Koborzan Melinda R.26,Guerrero Isabel27,Concha Pablo28,Barral Patricia29,Batlle Montserrat1,Cano Sílvia1,Garcia-Castrillon Silvia1,Andorrà Xavier1,Tua Yenifher1,Arnau Anna1,Fernández Rafael1

Affiliation:

1. Althaia Xarxa Assistencial Universitaria de Manresa

2. Hospital Universitario de Canarias

3. Araba University Hospital: Hospital Universitario Araba

4. Hospital de Mataro

5. Hospital Clinico Universitario

6. Granollers General Hospital: Hospital General de Granollers

7. Complexo Hospitalario de Ourense

8. Joan XXIII University Hospital in Tarragona: Hospital Universitari de Tarragona Joan XXIII

9. Henares Hospital: Hospital Universitario del Henares

10. Complexo Hospitalario de Pontevedra: Complejo Hospitalario Universitario de Pontevedra

11. Hospital Son Llatzer

12. Hospital Provincial Castellon

13. Hospital Universitario Marques de Valdecilla

14. Vall d'Hebron Hospital: Hospital Universitari Vall d'Hebron

15. Hospital General Universitario Santa Lucía: Hospital Universitario General de Santa Lucia

16. Hospital General Universitario de Elche

17. Hospital Universitari Sant Joan de Reus

18. Hospital Morales Meseguer: Hospital General Universitario Jose M Morales Meseguer

19. Hospital Arnau de Vilanova

20. Hospital Universitari MutuaTerrassa

21. Hospital Universitario de la Princesa

22. Hospital de Sagunto

23. Hospital Regional Universitario de Málaga: Hospital Regional Universitario de Malaga

24. Hospital Universitari Sagrat Cor

25. Hospital Universitario Central de Asturias

26. Hospital de Sant Joan Despí Moisès Broggi: Hospital de Sant Joan Despi

27. Hospital Universitario Virgen de las Nieves

28. Hospital Verge de la Cinta

29. Complexo Hospitalario Universitario de Santiago de Compostela: Complejo Hospitalario Universitario de Santiago de Compostela

Abstract

Abstract

Background: the best spontaneous breathing test (SBT) during weaning from mechanical ventilation is a 30-min test with pressure support ventilation (PSV) 8 cmH2O without positive end expiratory pressure (PEEP). There is a debate about the possible collapse of some alveolar units during such SBT and during extubation with continuous suctioning. A few experiences showed extubation without suctioning as feasible and safe. Lung ultrasound is an excellent tool to determine the level of lung aeration. We hypothesize that preserving lung volume during SBT and extubation can yield higher rates of successful extubation. Methods: Primary objective: To determine the rates of successful extubation in two extubation approaches aiming at different levels of lung volume preservation: standard SBT (30-min PSV8 without PEEP followed by extubation with continuous suctioning) versus experimental SBT (30-min PSV8 + PEEP5 followed by extubation without suctioning). Secondary objectives: To determine reintubation rate, ICU and hospital stays, the lung volume aeration using modified lung ultrasound score (LUS) before and after successful or failed SBT, diaphragm and intercostal thickness and thickening fraction by ultrasound (US) before and after successful or failed SBT. Design: Multi-center, randomized clinical trial. Eligible patients will be randomly assigned to a two opposing extubation strategies. The follow-up period will be 90-days after randomization. Discussion: A representative group of mechanically ventilated patients ready to be liberated from the ventilator will be studied in order to provide comprehensive data on the potential impact of preserving lung volume during weaning. Ethics and registration: The study has been approved by the Board Research Committee (CEIm) of the Fundació Unió Catalana d'Hospitals with the code CEI 22/67 and 23/26. Already registered on ClinicalTrials.gov Identifier: NCT05526053 on August 2023.

Publisher

Springer Science and Business Media LLC

Reference35 articles.

1. Peñuelas O, Frutos-Vivar F, Muriel A, Mancebo J, García-Jiménez A, de Pablo R et al. Mechanical ventilation in Spain, 1998–2016: Epidemiology and outcomes. Medicina Intensiva (English Edition) [Internet]. 2021;45(1):3–13. Available from: https://www.sciencedirect.com/science/article/pii/S2173572720301946.

2. Weaning from mechanical ventilation;Boles JM;Eur Respir J,2007

3. High-flow nasal cannula to prevent postextubation respiratory failure in high-risk non-hypercapnic patients: a randomized multicenter trial;Fernandez R;Ann Intensive Care,2017

4. Effect of postextubation high-flownasal cannula vs noninvasive ventilation on reintubation and postextubation respiratory failure in high-risk patients a randomized clinical trial;Hernández G;JAMA - Journal of the American Medical Association,2016

5. Reconnection to mechanical ventilation for 1 h after a successful spontaneous breathing trial reduces reintubation in critically ill patients: a multicenter randomized controlled trial;Fernandez MM;Intensive Care Med,2017