Discrepancies in Coronal Alignment Measurements between Full-length Weight-bearing Radiographs and Computed Tomography in Robotic Arm-assisted Total Knee Arthroplasty with the Mako System

Author:

Yang Hong Yeol1,Ayob Khairul2,Jeong Hwi Woo1,Seon Jong Keun1

Affiliation:

1. Chonnam National University Hwasun Hospital

2. University of Malaya

Abstract

Abstract

Introduction: Assessment of lower limb coronal plane alignment is crucial in surgical planning of total knee arthroplasty (TKA) and is commonly performed with full-length weight-bearing radiographs (FLWBR). The aim of this study was to determine discrepancies in coronal limb alignment as assessed by conventional FLWBR versus non-weight-bearing computed tomography (CT) modalities in robotic arm-assisted TKA performed using the Mako system (Stryker). Methods: We retrospectively analyzed 100 consecutive patients with osteoarthritic knees who underwent robotic arm-assisted TKA with preoperative FLWBR and CT assessments of knee alignment. The mechanical axes of the Mako system were established in accordance with the Mako TKA Surgical Guide. The following parameters were compared between the two imaging modalities: (1) mechanical hip-knee-ankle angle (mHKA), (2) medial proximal tibial angle (MPTA), (3) lateral distal femoral angle (LDFA), (4) arithmetic hip-knee-ankle angle (aHKA), (5) joint line obliquity (JLO), and (6) proportion of the coronal plane alignment of the knee (CPAK) types. Regression analyses were performed to identify potential factors associated with discrepancies in measurements of coronal alignment between these two imaging modalities. Results: There were significant differences in terms of the mHKA between preoperative CT and FLWBR (CT vs FLWBR, 7.0° vs. 8.5°; p < 0.001), which may be attributed to the extent of the weight-bearing condition. The CT measurements with the Mako system demonstrated a lower (more varus) MPTA than the FLWBR measurements (CT vs FLWBR, 83.7° vs. 85.2°; p < 0.001). Furthermore, there were also significant differences between the CT and FLWBR measurements in terms of the aHKA (−4.7° vs. −3.7°; p = 0.028) and JLO (172.2° vs. 174.2°; p < 0.001). There were significant differences of proportion of CPAK types between the two imaging modalities; however, the most common category was type I in both imaging modalities. Multivariate analyses showed that greater preoperative mHKA and posterior tibial slope were associated with the discrepancy in the MPTA measurements between the two imaging modalities. Conclusion: There were discrepancies in coronal alignment between preoperative FLWBR and non-weight-bearing CT using the Mako system. When compared with conventional FLWBR, the Mako system tended to overestimate the magnitude of tibial varus deformity in the knee joint. Level of Evidence: Level IV.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3