Biomechanical Evaluation of Unstable Intertrochanteric Fractures Fixation with Different Implants: A Finite Element Analysis Study

Author:

Qi Yuanbo1,Li Jiantao2,Xu Cheng2,Xiong Dou2,Wu Jie1,Wang Guoqi3,Wang Daofeng4,Liu Kaiyuan5,Tao Sheng1,Zhang Zhi1,Liu Daohong1

Affiliation:

1. The Eighth Medical Center of Chinese PLA General Hospital

2. The Fourth Medical Center of Chinese PLA General Hospital

3. National Clinical Research Center for Orthopaedics, Sports Medicine & Rehabilitation

4. Capital Medical University

5. Beijing University of Technology

Abstract

Abstract

Purpose Unstable intertrochanteric fractures are one of the most difficult to treat in older hip fractures. In this study, we simulated unstable intertrochanteric fractures AO/OTA 31 A2.3 by finite element analysis to compare the biomechanical stability of the three implants most commonly used in clinical treatment at this stage. Methods We used Mimics, Geomagic studio, UG-NX, Hypermesh and other software to establish the model of unstable intertrochanteric fracture (AO/OTA 31 A2.3) and three internal fixation models of Dynamic hip screw (DHS), Proximal Femoral Nail Antirotation (PFNA), and InterTAN. After assembly, Abaqus software was used to analyze and calculate the Von Mises stress distribution, strain distribution, and displacement distribution of each group of fracture internal fixation models when the force was applied in the gait. Results Our experimental results show that under 2100N load, the peak stress of the InterTAN was 783.4Mpa, while the peak stress of PFNA and DHS was 603.7Mpa and 763.5Mpa. In InterTAN, the peak strain was 0.41% at the load of 2100N; in PFNA, the peak strain was 0.58%; in DHS, the peak strain was 0.69%. And InterTAN structure had a maximum displacement of 5.74 mm at a load of 2100N. PFNA structure performed the maximum displacement of 9.44 mm, and DHS was 21.76 mm. The maximum displacement of the complete fracture model under InterTAN fixation was 6.7 mm, and the maximum displacement values for the PFNA fixation model and DHS fixation model were 10.84 mm and 22.8 mm. Conclusions Our finite element analysis results indicate that when subjected to the same mechanical loads, InterTAN experiences lower yield strain and displacement compared to DHS and PFNA. Only under higher loads does InterTAN exhibit higher peak stress. It demonstrates superior biomechanical performance, making it a better choice for fixing unstable intertrochanteric fractures. Additionally, intramedullary fixation proves to be more effective than extramedullary fixation.

Publisher

Springer Science and Business Media LLC

Reference40 articles.

1. A critical review of the long-term disability outcomes following hip fracture;Dyer SM;BMC GERIATR,2016

2. Global, regional, and national burden of bone fractures in 204 countries and territories, 1990–2019: a systematic analysis from the Global Burden of Disease Study 2019;Wu A;The Lancet Healthy Longevity,2021

3. Intertrochanteric versus femoral neck hip fractures: differential characteristics, treatment, and sequelae;Fox KM;J Gerontol A Biol Sci Med Sci,1999

4. Orthogeriatric care-outcome of different fragility fractures;Pankratz C;Arch Orthop Trauma Surg,2023

5. Simunovic N, Devereaux PJ, Sprague S, Guyatt GH, Schemitsch E, Debeer J et al. Effect of early surgery after hip fracture on mortality and complications: systematic review and meta-analysis. Canadian Medical Association journal (CMAJ). 2010;182(15):1609-16. 'doi:'10.1503/cmaj.092220.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3