Abstract

Abstract Background Accurate calculation of lung cancer dose using the Monte Carlo (MC) algorithm in CyberKnife is essential for precise planning. We aim to employ deep learning to directly predict the 3D dose distribution calculated by the MC algorithm, enabling rapid and accurate automatic planning. However, most current methods solely focus on conventional intensity-modulated radiation therapy and assume a consistent beam configuration across all patients. This study seeks to develop a more versatile model incorporating variable beam configurations of CyberKnife and considering the patient's anatomy. Methods This study proposed the AB (anatomy and beam) model to compare with the control Mask (only anatomy) model. These models are based on a 3D U-Net network to investigate the impact of CyberKnife beam encoding information on dose prediction. The study collected 86 lung cancer patients who received the built-in MC algorithm plans of CyberKnife using different beam configurations for training/validation (66 cases) and testing (20 cases). We compared the gamma passing rate, dose difference maps, and relevant dose-volume metrics to evaluate the model's performance. In addition, the Dice similarity coefficients (DSCs) was calculated to assess the spatial correspondence of isodose volumes. Results The AB model demonstrated superior performance compared to the Mask model, particularly in the trajectory dose of the beam. The DSCs of the AB model was 20–40% higher than that of the Mask model in some dose regions. We achieved approximately 99% for the PTV and generally more than 95% for the organs at risk (OARs) referred to the clinical planning dose in the gamma passing rates (3mm/3%). Relative to the Mask model, the AB model exhibited more than 90% improvement in small voxels (P < 0.001). The AB model matched well with the clinical plan's dose-volume histograms (DVHs) and the average dose error for all organs was 1.65 ± 0.69%. Conclusions Our proposed new model signifies a crucial advancement in predicting CyberKnife 3D dose distributions for clinical applications. It enables planners to rapidly and precisely calculate MC doses for lung cancer based on patient-specific beam configurations.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3