A report of radiotherapy setup errors in pelvic and mediastinal tumors

Author:

Hasoomi Nafise1,Azizi Azam1,Ranjbar Somayeh Amin1

Affiliation:

1. Tehran University of Medical Science

Abstract

Abstract Introduction: Radiation therapy as an important step in treatment of cancer which demands accuracy. Patient setup is a challenging job in the radiation therapy process. The Variation in random setup error for specific sites is different among clinics, even from one radiation therapist technologist to other in a same clinic. The purpose of this study is to investigate and report about the setup margins in the pelvic and mediastinal sites. Method &Material: 34 patients (20 males and 14 females) in the supine and prone positions (24 supine positions and 10 prone positions) were selected. Internal protocol and custom-made positioning devices were utilized. The variation of Anterior-Posterior movements (AP) in daily setup is recorded based on the vertical information which is shown on the arian 2100C/D Linear Accelerators monitor. The correlation between body type, position and treatment cases compares with the mean errors. Conclusion: The highest random error for setup is attributed to mediastinal tumor (= 0.3 cm), and the highest systematic error is dedicated to cervix (= 1.4 cm). The population systematic error (= 1.25) is defined as the standard deviation of means of patients(Σ). In centers with lack of image-guided facilities or centers with high loaded patients the setup process should be accurate enough to limit setup error probabilities.

Publisher

Research Square Platform LLC

Reference21 articles.

1. Prevention of gross setup errors in radiotherapy with an efficient automatic patient safety system;Yan G;Journal of Applied Clinical Medical Physics,2013

2. A review of setup error in supine breast radiotherapy using cone-beam computed tomography;Batumalai V;Medical Dosimetry,2016

3. 5 whys;Jones G;Lean & Six Sigma Review,2021

4. Pitkänen, M., Mould room techniques in radiotherapy. 1987: VTT Technical Research Centre of Finland.

5. improved positioning protocol for patient setup accuracy in conventional radiotherapy for lung cancer;Chai H;Radiological Physics and Technology,2019

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3