The Impact of Repeated Preheating of Matrix Modifying Bulk Fill Resin Composite on Post-gel Polymerization Shrinkage Strain (in Vitro Study)

Author:

fathy Heba1,Gamal Wael1,Riad Mona2

Affiliation:

1. Modern University for Technology and Information (MTI)

2. Cairo University

Abstract

Abstract Background: This study evaluated the effect of repeated preheating cycles of matrix-modifying bulk fill resin composites on the postgel polymerization shrinkage strain. Methods: Forty resin composite specimens were prepared using a Teflon mold (7 mm length x 4 mm width x 2 mm height). Each specimen was linked to a strain gauge and strain monitoring equipment (Strain-Meter PCD-300A Kyowa-Electronic Instruments Co, LTD, Tokyo, Japan) for measuring the postgel polymerizationshrinkage strain (um/m) of the resin composite. Preheating of the resin composite syringe was accomplished using Active Resin Heat (temperature of 68°C). According to the number of preheating cycles of the resin composite syringes, the specimens were divided into four equal groups: P0 (control), resin composite packed and cured at room temperature [23 ± 1°C], P1: preheated once, P2: preheated twice and P3: preheated three times prior to packing and curing for 30 seconds according to the manufacturer’s instructions. Statistical analysis was performed using Shapiro‒Wilk test for normality. ANOVA single factor was used as the test of significance followed by Tukey Hsd/Kramer with the level of significance set at 0.05. Results: Data analysis revealed insignificant differences in the postgel polymerization shrinkage strain among all tested groups (p≥0.05). Conclusions: The repeated preheating cycles of matrix-modifying bulk-fill resin composites prior to curing had no adverse effect on the induced postgel polymerization shrinkage strain. Clinical Relevance: The results of this study confirmed that clinicians can consider repeatedly preheating resin composites in dental practices. The information of comparable performance regarding postgel polymerization shrinkage when applying preheated composites as room temperature cured resin composites could be of utmost significance as the same resin composite syringe can clinically undergo numerous preheating cycles before it is completely consumed with the advantage of a transient reduction in viscosity, improving restoration adaptability to the cavity. Its use in routine care can be considered a good practice.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3