Comparison of pediatric lens dose measurements between axial and helical scan modes using a 160-mm volume computed tomography scanners.

Author:

Masuda Takanori1ORCID,Kiguchi Masao2,Fujioka Chikako2,Oku Takayuki3,Ishibashi Toru3,Yoshitake Takayasu4,Awai Kazuo5

Affiliation:

1. Tsuchiya Sogo Byoin

2. Hiroshima University Hospital: Hiroshima Daigaku Byoin

3. Tsuchiya General Hospital: Tsuchiya Sogo Byoin

4. TOWCAR WORKS Co.,ltd

5. Hiroshima University - Kasumi Campus: Hiroshima Daigaku - Kasumi Campus

Abstract

Abstract Purpose To compare the scatter dose for lenses between a helical scan with a 40-mm detector width and an axial scan with a 160-mm detector width when using different computed tomography (CT) scanners in pediatric chest CT examinations. Methods Two CT devices, Revolution CT and Aquilion ONE, and three pediatric anthropomorphic phantoms were used, with optically stimulated luminescence dosimeters (OSLDs) placed on the left and right lenses. The measured scatter dose values of the OSLD were compared between the helical scan with the 40-mm detector width and axial scan with the 160-mm detector width in the different phantoms during the pediatric chest CT examinations. Results With the Revolution CT, no significant differences in the scatter doses between the 40-mm detector width for the helical scan and 160-mm detector width for the axial scan in the newborn and 1-year-old phantoms were observed. However, the lens scatter dose for the helical scan with the 40-mm detector width was approximately 20% higher than that for the axial scan with the 160-mm detector width in the 5-year-old phantom (p < 0.01). With the Aquilion ONE, the lenses scatter dose for the 40-mm detector width for the helical scan was approximately 70%, 40%, and 30% higher in newborn, 1-year-old, and 5-year-old phantoms, respectively, than that for the 160-mm detector width for the axial scan (p < 0.01). Conclusions The lenses scatter doses for the 40-mm detector width for the helical scan was higher in all phantoms than that for the 160-mm detector width for the axial scan.

Publisher

Research Square Platform LLC

Reference29 articles.

1. Pediatric 320-row cardiac computed tomography using electrocardiogram-gated model-based full iterative reconstruction;Shirota G;Pediatr Radiol,2017

2. Comparison of image quality between synthetic and patients' electrocardiogram-gated 320-row pediatric cardiac computed tomography;Maeda E;Pediatr Radiol,2020

3. Imaging pediatric acute head trauma using 100-kVp low dose CT with adaptive statistical iterative reconstruction (ASIR-V) in single rotation on a 16†Šcm wide-detector CT;Zhu Y;J Xray Sci Technol,2021

4. Further Improving Image Quality of Cardiovascular Computed Tomography Angiography for Children With High Heart Rates Using Second-Generation Motion Correction Algorithm;Sun J;J Comput Assist Tomogr,2020

5. Radiation Dose for Pediatric CT: Comparison of Pediatric versus Adult Imaging Facilities;Strauss KJ;Radiology,2019

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3