Q.Clear Reconstruction for Reducing the Scanning Time for 68Gallium-DOTA-FAPI-04 PET/MR Imaging

Author:

Ruan Weiwei1,Qin Chunxia1,Liu Fang1,Pi Rundong1,Gai Yongkang1,Liu Qingyao1,Lan Xiaoli2ORCID

Affiliation:

1. Wuhan Union Hospital

2. Department of Nuclear Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science & Technology

Abstract

Abstract Purpose: To determine whether Q.Clear positron emission tomography (PET) reconstruction may reduce tracer injection dose or shorten scanning time in 68Ga fibroblast activation protein inhibitor (FAPI) PET/magnetic resonance (MR) imaging. Methods: We retrospectively collected cases of 68Ga-FAPI whole-body imaging performed on integrated PET/MR. PET images were reconstructed using three different methods: Ordered Subset Expectation Maximization (OSEM) reconstruction with full scanning time, OSEM reconstruction with half scanning time, and Q.Clear reconstruction with half scanning time. We then measured standardized uptake values (SUVs) within and around lesions, alongside their volumes. We also evaluated image quality using lesion-to-background (L/B) ratio and signal to noise ratio (SNR). We then compared these metrics across the three reconstruction techniques using statistical methods. Results: Q.Clear reconstruction significantly increased SUVmax and SUVmean within lesions (by almost 40%) and reduced their volumes in comparison with OSEM reconstruction. Background SUVmax also increased significantly, while background SUVmean showed no difference. Average L/B values for Q.Clear reconstruction were only marginally higher than those from OSME reconstruction with half-time (full-time). SNR decreased significantly in Q.Clear reconstruction compared with OSEM reconstruction with full time (but not half time). Differences between Q.Clear and OSEM reconstructions in SUVmax and SUVmean values within lesions were significantly correlated with SUVs within lesions. Conclusions: Q.Clear reconstruction was useful for reducing PET injection dose or scanning time while maintaining the image quality. Q.Clear may affect PET quantification and it is necessary to establish diagnostic recommendations based on Q.Clear results for Q.Clear application.

Publisher

Research Square Platform LLC

Reference25 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3