Comparing Medical Record Abstraction (MRA) Error Rates in an Observational Study to Pooled Rates Identified in the Data Quality Literature

Author:

Garza Maryam Y.1,Williams Tremaine B.1,Ounpraseuth Songthip1,Hu Zhuopei1,Lee Jeannette1,Snowden Jessica1,Walden Anita C.2,Simon Alan E.3,Devlin Lori A.4,Young Leslie W.5,Zozus Meredith N.6

Affiliation:

1. University of Arkansas for Medical Sciences

2. University of Colorado Denver, Anschutz Medical Campus

3. Centers for Disease Control and Prevention

4. University of Louisville

5. University of Vermont

6. University of Texas Health Science Center at San Antonio, Joe R. & Teresa Lozano Long School of Medicine

Abstract

Abstract Background: Medical record abstraction (MRA) is a commonly used method for data collection in clinical research, but is prone to error, and the influence of quality control (QC) measures is seldom and inconsistently assessed during the course of a study. We employed a novel, standardized MRA-QC framework as part of an ongoing observational study in an effort to control MRA error rates. In order to assess the effectiveness of our framework, we compared our error rates against traditional MRA studies that had not reported using formalized MRA-QC methods. Thus, the objective of this study was to compare the MRA error rates derived from the literature with the error rates found in a study using MRA as the sole method of data collection that employed an MRA-QC framework. Methods: Using a moderator meta-analysis employed with Q-test, the MRA error rates from the meta-analysis of the literature were compared with the error rate from a recent study that implemented formalized MRA training and continuous QC processes. Results: The MRA process for data acquisition in clinical research was associated with both high and highly variable error rates (70 – 2,784 errors per 10,000 fields). Error rates for the study using our MRA-QC framework were between 1.04% (optimistic, all-field rate) and 2.57% (conservative, populated-field rate) (or 104 – 257 errors per 10,000 fields), 4.00 – 5.53 percentage points less than the observed rate from the literature (p<0.0001). Conclusions: Review of the literature indicated that the accuracy associated with MRA varied widely across studies. However, our results demonstrate that, with appropriate training and continuous QC, MRA error rates can be significantly controlled during the course of a clinical research study.

Publisher

Research Square Platform LLC

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3