On the measurement of scaling factors in the RW3 plastic phantom during high energy electron beam dosimetry

Author:

Baghani Hamid Reza1,Andreoli Stefano2ORCID,Robatjazi Mostafa3

Affiliation:

1. Hakim Sabzevari University

2. ASST Papa Giovanni XXIII: Aziende Socio Sanitarie Territoriale Papa Giovanni XXIII

3. Sabzevar University of Medical Sciences

Abstract

Abstract Ionometric electron dosimetry inside water-equivalent plastic phantoms demands special considerations including determination of depth scaling and fluence scaling factors (cpl and hpl) to shift from in-phantom measurements to those relevant to water. This study evaluates these scaling factors for RW3 slab phantom and also introduce a new coefficient, k(RW3), for direct conversion from RW3 measurements to water without involving scaling factors. The RW3 solid phantom developed by the PTW Company was used and the corresponding scaling factors including cpl, hpl, and k(RW3) were measured for conventional electron energies of 4, 6, 9, 12, and 16 MeV. Separate measurements were performed in water and in the RW3 slab phantom using the Advanced Markus chamber. The validity of the reported scaling factors was confirmed by comparing the direct and indirect percentage depth dose (PDD) measurement in water and in the RW3 phantom. The cpl values for the RW3 phantom were respectively equal to 0.915, 0.927, 0.934, 0.937, and 0.937 for 4, 6, 9, 12, and 16 MeV electron energies. The hpl and k(RW3) values were dependent on the investigation depth and on the electron energy. Application of the cpl-hpl factors and of the k(RW3) coefficients to measured data inside the RW3 can reliably reproduce the measured PDD curves in water. The mean difference between the PDDs measured directly and indirectly in water and in the RW3 phantom was less than 1.5% in both approaches for PDD conversion (cpl-hpl coupling and the use of k(RW3)). The scaling factors measured and the k(RW3) coefficients are sufficiently relevant to mimic water-based dosimetry results through indirect measurements inside the RW3 slab phantom. Nevertheless, employing k(RW3) is more straightforward than the cpl-hpl approach because it does not involve scaling and it is also less time-consuming.

Publisher

Research Square Platform LLC

Reference37 articles.

1. Role of radiotherapy in melanoma management;Strojan P;Radiol Oncol,2010

2. Therapeutic approaches in the management of locally advanced rectal cancer;Fung-Kee-Fung SD;J Gastrointest Oncol,2014

3. Review of electron beam therapy physics;Hogstrom KR;Phys Med Biol,2006

4. A review on radiochromic film dosimetry for dose verification in high energy photon beams;Santos T;Rad Phys Chem,2021

5. A systematic literature review of the clinical and cost-effectiveness of hadron therapy in cancer;Lodge M;Radiother Oncol,2007