The C2 isthmus screw provided sufficient biomechanical stability in the setting of atlantoaxial dislocation

Author:

Lu Minming1,Wang Zhenqiang1,Yuan Bo1,Tang Yifan1,Gu Changjiang1,Zhou Shengyuan1,Chen XiongSheng1

Affiliation:

1. Shanghai Changzheng Hospital

Abstract

Abstract Background. The emerging of the C2 isthmus screw fixation technique is gaining popularity in the setting of atlantoaxial dislocation or other conditions requiring fixation of C2. However, the biomechanical stability of this fixation is poorly understood. Purpose. To compare and elucidate the biomechanical stability of C2 pedicle screw (C2PS), C2 isthmus screw (C2IS) and C2 short isthmus screw (C2SIS) fixation techniques in atlantoaxial dislocation (AAD). Method. A three-dimensional finite element model (FEM) from occiput to C3 was established and validated from a healthy male volunteer. Three FEMs, C1 pedicle screw (PS)-C2PS, C1PS-C2IS, C1PS-C2SIS were also constructed. The range of motion (ROM) and the maximum von Mises under flexion, extension, lateral bending and axial rotation loading were analysed and compared. The pullout strength of the three fixations for C2 were also evaluated. Result. C1PS-C2IS showed the greatest decrease in ROM with flexion, extension, lateral bending and axial rotation. C1PS-C2PS showed the least ROM reduction under all loading condition than both C2IS and C2SIS. The C1PS-C2PS model had the largest von Mises under all directions followed by C1PS-C2SIS, and lastly the C1PS-C2IS. Under axial rotation and lateral bending loading, the three models showed the largest and least von Mises stress respectively. The stress of the three models was mainly located in the connection of the screw and rod. Overall, the maximum pullout strength for C2PS, C2IS and C2SIS were 729.41N, 816.62N, 640.54N respectively. Conclusion. In patients with atlantoaxial dislocations, the C2IS fixation provided comparable stability, with no significant stress concentrations. Furthermore, the C2IS had sufficient pullout strength when compared with C2PS and C2SIS. C2IS is an effective and safe fixation modality in the treatment of atlantoaxial dislocations.

Publisher

Research Square Platform LLC

Reference34 articles.

1. Current dilemmas in Down syndrome clinical care: celiac disease, thyroid disorders, and atlanto-axial instability;Cohen WI;Am J Med Genet C Semin Med Genet,2006

2. Posterior C1-C2 fusion with polyaxial screw and rod fixation;Harms J;Spine (Phila Pa 1976),2001

3. Plate and screw fixation for atlanto-axial subluxation;Goel A;Acta Neurochir (Wien),1994

4. Goel A, Desai KI, Muzumdar DP. Atlantoaxial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery, 2002. 51(6): p. 1351-6; discussion 1356-7.

5. Stabilization of the atlantoaxial complex via C-1 lateral mass and C-2 pedicle screw fixation in a multicenter clinical experience in 102 patients: modification of the Harms and Goel techniques;Aryan HE;J Neurosurg Spine,2008

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3