Affiliation:
1. S L Raheja Hospital (A Fortis Associate)
Abstract
Abstract
Background Cardiac output (CO) and stroke volume (SV) monitoring are cornerstones of hemodynamic management in patients at risk of shock. The multi-beat analysis (MBA) method provides continuous estimates of CO and SV by analysis of a patient’s arterial blood pressure waveform. In this study we assessed the agreement of CO and SV between 2D echocardiography (CO-ECHO and SV-ECHO) and the multi-beat analysis (MBA) method via the Argos monitor (CO-MON and SV-MON).Methods Fifty patients with a wide range of diagnoses were prospectively enrolled in the ICU in this observational, method comparison study. One set of paired, simultaneous measurements was recorded for each patient.Results for the 50 included data points in the study the mean difference between CO-ECHO and CO-MON was − 0.05 ± 0.58 L/min with limits of agreement from − 1.18 to + 1.08 L/min and a percentage error of 21.5%. The mean difference between SV-ECHO and SV-MON was − 0.9 ± 6.6 mL with limits of agreement from − 13.9 to + 12.0 mL and a percentage error of 22.8%.Conclusion Accuracy of the MBA method was clinically acceptable as compared to 2D echocardiography.
Publisher
Research Square Platform LLC
Reference12 articles.
1. Cecconi M, De Backer D, Antonelli M. etal.Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine.Intensive Care Med.2014;40(12):1795–1815.doi:10.1007/s00134-014-3525-z
2. Saugel B, Kouz K, Scheeren TWL. etal.Cardiac output estimation using pulse wave analysis-physiology, algorithms, and technologies : a narrative review.Br J Anaesth.Published online 2020.doi:10.1016/j.bja.2020.09.049
3. Lu Z, Mukkamala R. Continuous cardiac output monitoring in humans by invasive and noninvasive peripheral blood pressure waveform analysis.J Appl Physiol (1985).2006;101(2):598–608.doi:10.1152/japplphysiol.01488.2005
4. Greiwe G, Peters V, Hapfelmeier A, Romagnoli S, Kubik M, Saugel B. Cardiac output estimation by multi-beat analysis of the radial arterial blood pressure waveform versus intermittent pulmonary artery thermodilution: a method comparison study in patients treated in the intensive care unit after off-pump coronary artery by.J Clin Monit Comput.2019;34(4):643–648.doi:10.1007/s10877-019-00374-0
5. Saugel B, Heeschen J, Hapfelmeier A, Romagnoli S, Greiwe G. Cardiac output estimation using multi-beat analysis of the radial arterial blood pressure waveform: a method comparison study in patients having off-pump coronary artery bypass surgery using intermittent pulmonary artery thermodilution as the reference me.J Clin Monit Comput.2020;34(4):649–654.