Affiliation:
1. Binzhou Medical University
2. Affiliated Hospital of Binzhou Medical College
Abstract
AbstractObjective Evaluation of the accuracy and effectiveness of 3D printed guides to assist femoral tunnel preparation in individualised reconstruction of the anterior cruciate ligament. Design Randomised controlled studies. Patients/participants Sixty patients who attended the Affiliated Hospital of Binzhou Medical College for autologous hamstring single bundle reconstruction of the anterior cruciate ligament from October 2018 to October 2020 were selected and randomly divided into two groups, including 31 cases in the 3D printing group (14 males and 17 females, mean age 41.94 ± 10.15 years) and 29 cases in the control group (13 males and 16 females, mean age 37.76 ± 10.34 years). Main outcome measures Patients in both groups were assessed for intraoperative femoral tunnel accuracy, the number of intraoperative positioning and the time taken to prepare the femoral tunnel, the length of the anteromedial approach incision, the pre-planned bone tunnel length and intraoperative bone tunnel length in the 3D printed group, IKDC score and Lysholm score preoperatively and at 3, 6 and 12 months postoperatively, the Lachman、pivot-shift test preoperatively and at 6 months postoperatively, gait analysis to assess internal and external rotation in flexion of the knee at 12 months postoperatively and postoperative complications in both groups. Results There was no statistical difference in functional knee scores and anteromedial approach incision length between the 3D printed and control groups (p > 0.05), while there was a statistical difference in the accuracy of tunnel positioning, the time taken to prepare the femoral bone tunnel and the degree of external rotation of the knee in flexion between the two groups (p < 0.05). There was no statistical difference between the preoperative planning of the bone tunnel length and the intraoperative bone tunnel length (p > 0.05). Complications: One case in the 3D printing group developed intermuscular vein thrombosis in the affected lower limb after surgery, which disappeared after treatment, while three cases in the control group developed intermuscular vein thrombosis in the affected lower limb. No complications such as bone tunnel rupture, deep vein thrombosis in the lower limb and infection occurred in either group. Conclusions 3D printed guides assisted with individualized ACL reconstruction can improve the accuracy of femoral tunnel positioning, which is safe and effective, while reducing the operative time and the number of intraoperative positioning, without increasing the length of incision, and can obtain higher functional scores and rotational stability of the knee joint, which is in line with the concept of individualized ACL reconstruction. Level of Evidence Therapeutic Level Ⅰ.
Publisher
Research Square Platform LLC