Affiliation:
1. Universiti Malaysia Sarawak
2. Universiti Teknologi Malaysia
Abstract
Abstract
Background
The revolutionary technology of smartphone-based retinal imaging has been consistently improving over the years. Smartphone-based retinal image acquisition devices are designed to be portable, and easy to use, besides being low-cost which enables eye care to be more widely accessible especially in geographically remote areas. This enables early disease detection for those who are in low- and middle- income population or just in general has very limited access to eye care. This study investigates the limitation of smartphone compatibility of existing smartphone-based retinal image acquisition devices. Additionally, this study aims to propose a universal adapter that is usable with an existing smartphone-based retinal image acquisition device, the PanOptic ophthalmoscope. This study also aims to simulate the reliability, validity, and performance overall of improved develop prototype. Existing studies have shown that the concept of smartphone-based retinal imaging is still limited to screening purposes only. Furthermore, existing smartphone-based devices also have a limited smartphone compatibility where it is only usable with specific smartphone models.
Methods
A literature review was conducted that identifies the limitation of smartphone compatibility among existing smartphone-based retinal image acquisition devices. Designing and modelling of proposed adapter was performed using the software AutoCAD 3D. For proposed performance evaluation, finite element analysis (FEA) in the software Autodesk Inventor and 5-point scale method were applied.
Results
It was identified how a universal adapter is beneficial in broadening the usability of existing smartphone-based retinal image acquisition devices as most of the devices that are available in the market have limited smartphone compatibility. A functional universal adapter was developed and found to be suitable with two smartphones that have different camera placement and dimensions. The proposed performance evaluation method was able to generate efficient stress analysis of the proposed adapter design.
Conclusion
The concept of a universal and suitable adapter for retinal imaging using the PanOptic ophthalmoscope was presented in this paper. Performance evaluation methods proposed were identified to be sufficient to analyze the behavior of proposed adapter when an external load is applied and determine its suitability with the PanOptic ophthalmoscope.
Publisher
Research Square Platform LLC