Abstract

Abstract INTRODUCTION : Proximal humerus fractures are usually treated with rigid angle-stable plates or nails. As an alternative, semi-rigid, minimally invasive systems have been developed for supportive fixation. A new system uses this principle with 2.5 mm partially threaded pins and external fixation. AIM: This study aimed to compare the fracture stability of the fixator with an angular stable plate about whether the mechanical stability is sufficient for early postoperative mobilisation. MATERIALS and METHODS: Human proximal humeri (paired, female, age ≥ 60, n = 8) were cut to a 3-part fracture and treated with an external fixator (Galaxy Shoulder, Orthofix) or an angular stable plate (Philos, DePuy Synthes). A physiological load was simulated based on a 45° abduction motion. The load level was continuously increased from 10 to 320 N within 10,000 cycles simulating the loads during rehabilitation. This was followed by another 10,000 cycles at 320 N for fatigue testing. Fracture motion was recorded with a 3D camera. Fracture stability was evaluated at a partial load of 160 N (simulating loads during early mobilisation). RESULTS: The fracture motion at the lateral aspect was significantly (p < 0.03) larger for the fixator compared to the plate both for axial and for shear movements, while at the medial aspects fracture motions were similar. Both fixation systems adequately stabilized the lateral tubercle fragment with no significant differences between fixation techniques. The migration of the fixator pins (1.1 ± 1.0 mm) and valgus rotation of the head fragment were minimal (3.1 ± 2.0°). The maximum load level of 320 N was reached by 7 plate constructs and 2 fixator constructs. CONCLUSION: Our results suggest that the external fixator system allows early but gentle postoperative mobilisation. More aggressive rehabilitation measures should be postponed after the healing of the fracture.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3