Classifying physical activity levels using Mean Amplitude Deviation in adults using a chest worn accelerometer: validation of the Vivalink ECG Patch

Author:

Luckhurst Jim1,Hughes Cara1,Shelley Benjamin1

Affiliation:

1. University of Glasgow

Abstract

Abstract

Background: The development of readily available wearable accelerometers has enabled clinicians to objectively monitor physical activity (PA) remotely in the community, a superior alternative to patient self-reporting measures. Critical to the value of these monitors is the ability to reliably detect when patients are undergoing ambulatory activity. Previous studies have highlighted the strength of using mean amplitude deviation (MAD) as a universal measure for analysing raw accelerometery data and defining cut-points between sedentary and ambulatory activities. Currently however there is little evidence surrounding the use of chest-worn accelerometers which can provide simultaneous monitoring of other physiological parameters such as heart rate (HR), RR intervals, and Respiratory Rate alongside accelerometery data. We aimed to calibrate the accelerometery function within the VivaLink ECG patch to determine the cut-point MAD value for differentiating sedentary and ambulatory activities. Methods: We recruited healthy volunteers to undergo a randomised series of 9 activities that simulate typical free-living behaviours, while wearing a VivaLink ECG Patch (Campbell, California). MAD values were applied to a Generalised Linear Mixed Model to determine cut-points between sedentary and ambulatory activities. We constructed a Receiver Operating Characteristic (ROC) curve to analyse the sensitivity and specificity of the cut-off MAD value. Results: Eighteen healthy adults volunteered to the study and mean MAD values were collected for each activity. The optimal MAD cut-point between sedentary and ambulatory activities was 47.73mG. ROC curve analysis revealed an area under the curve of 0.99 (p<0.001) for this value with a sensitivity and specificity of 98% and 100% respectively. Conclusion In conclusion, the MAD cut-point determined in our study is very effective at categorising sedentary and ambulatory activities among healthy adults and may be of use in monitoring PA in the community with minimal burden. It will also be useful for future studies aiming to simultaneously monitor PA with other physiological parameters via chest worn accelerometers.

Publisher

Research Square Platform LLC

Reference28 articles.

1. Kumar K, Sharma A, Tripathi SL. Sensors and their application. Elsevier Inc.; 2021. https://doi.org/10.1016/B978-0-323-85172-5.00021-6.

2. The use of accelerometer-based wearable activity monitors in clinical settings: current practice, barriers, enablers, and future opportunities;Maher C;BMC Health Serv Res,2021

3. Benefits of Physical Activity. Centers Dis Control Prev 2023. https://www.cdc.gov/physicalactivity/basics/pa-health/index.htm#:~:text=Regular physical activity is one,ability to do everyday activities. (accessed September 20, 2023).

4. A comparison of direct versus self-report measures for assessing physical activity in adults: a systematic review;Prince SA;Int J Behav Nutr Phys Act,2008

5. A systematic review of reliability and objective criterion-related validity of physical activity questionnaires;Helmerhorst HHJ;Int J Behav Nutr Phys Act,2012

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3