Affiliation:
1. The Third Affiliated Hospital of Southern Medical University
2. Southern Medical University
Abstract
Abstract
Background: Accurate preoperative planning is an important step for accurate reconstruction in total hip arthroplasty (THA). Presently, preoperative planning is completed using either a two-dimensional (2D) template or three-dimensional (3D) mimics software. With the development of artificial intelligence (AI) technology, AI HIP, a planning software based on AI technology can quickly and automatically identify acetabular and femur morphology, and automatically match the optimal prosthesis size. However, the accuracy and feasibility of its clinical application still needs to be further verified. The purposes of this study were to investigate the accuracy and time efficiency of AI HIP in preoperative planning for primary THA, compared with 3D mimics software and 2D digital template; and further analyze the factors that influence the accuracy of AI HIP.Methods: A prospective study was conducted on 53 consecutive patients (59 hips) undergoing primary THA with cementless prostheses in our department. All preoperative planning was completed using AI HIP as well as 3D mimics and 2D digital template. The predicted component size and the actual implantation results were compared to determine the accuracy. The templating time was compared to determine the efficiency. Furthermore, the potential factors influencing the accuracy of AI HIP were analyzed including sex, body mass index (BMI), and hip dysplasia.Results: The accuracy in predicting the acetabular cup and femoral stem was 74.58% and 71.19%, respectively, for AI HIP; 71.19% (P = 0.743) and 76.27% (P = 0.468), respectively, for 3D mimics; 40.68% (P < 0.001) and 49.15% (P = 0.021), respectively, for 2D digital templating. The templating time using AI HIP was 3.91±0.64 min, which was equivalent to 2D digital templates (2.96±0.48 min, P < 0.001), but shorter than 3D mimics (32.07±2.41 min, P < 0.001). Acetabular dysplasia(P = 0.021), rather than sex and BMI, was an influential factor in the accuracy of AI HIP templating. Compared to patients with developmental dysplasia of the hip (DDH), the accuracy of acetabular cup in the non-DDH group was better (P = 0.021), but the difference in the accuracy of the femoral stem between the two groups was statistically insignificant (P = 0.062).Conclusion: AI HIP showed excellent reliability for component size in THA. Acetabular dysplasia may affect the accuracy of AI HIP templating.
Publisher
Research Square Platform LLC
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献