­Ultrasonic implant site preparation vs conventional drilling: in vitro evaluation of implant site diameter.

Author:

Lahoud Pierre1,Nasr Joseph Abi1,Menhall Abdallah1,Makary Christian1

Affiliation:

1. Saint Joseph University

Abstract

Abstract Objective The aim of this study is to evaluate implant site diameter after bony preparation using either conventional drilling (CD) or ultrasonic implant site preparation (UISP). Materials and Methods On bovine ribs, 3mm x 10mm implant sites were prepared using two different ultrasonic protocols, UISP1 (n = 16) and UISP2 (n = 16) and a conventional drilling protocol CD (n = 16). Implant sites were then filled with resin and both cortical and cancellous horizontal sections were made in order to measure the bucco-lingual (D1) and the mesio-distal (D2) diameters of each site. Also, implant sites were prepared on bovine ribs following UISP1 (n = 12), UISP2 (n = 12) and CD (n = 12) protocols and final insertion torque (IT) was measured for each preparation. The results were statistically analyzed using the Kruskal Wallis test. Results Statistically significant differences were found between UISP1 (mean diameter = 3.161) and CD (mean diameter = 3.012) for D1 (P = 0.041), between UISP1 (mean diameter = 3.328) and CD (mean diameter = 3.039) for D2 (P = 0.001), between UISP1 (mean diameter = 3.328) and UISP2 (mean diameter = 3.005) for D2 (P < 0.001). No statistically significant differences were noted between UISP1 (mean diameter = 3.161) and UISP2 (mean diameter = 2.995) for D1 (p-value = 0.08), between CD (mean diameter = 3.012) and UISP2 (mean diameter = 2.995) for D1 (p-value = 0.290), and between CD (mean diameter = 3.039) and UISP 2 (mean diameter = 3.005) for D2 (p-value = 0.650). A significant difference was noted between UISP1-IT values (mean torque = 17.96 N/cm) and both UISP2-IT values (mean torque = 37.48 N/cm) (P < 0.001) and CD-IT values (mean torque = 40.99 N/cm) (P < 0.001). No statistically significant difference was noted between CD-IT (mean torque = 40.99 Ncm) and UISP2-IT (mean torque = 37.48 Ncm) (p-value = 0.488). Conclusion By following proper protocol UISP can be used as precisely as CD to prepare implant bed.

Publisher

Research Square Platform LLC

Reference30 articles.

1. The effect of thread pattern upon implant osseointegration;Abuhussein H;Clin Oral Implants Res,2010

2. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man;Albrektsson T;Acta Orthop Scand,1981

3. Piezoelectric versus conventional implant site preparation: A systematic review and meta-analysis;Atieh MA;Clin Implant Dent Relat Res,2018

4. Piezoelectric vs. conventional implant site preparation: ex vivo implant primary stability;Baker JA;Clin Oral Implants Res,2012

5. Branemark P-I. Tissue Integrated Prostheses. Chicago: Quintessence Publishing; 1985.